Emerson NT5C06D user manual Contents

Page 7

 

7

Contents

 

Introduction

11

Description

11

Applications

12

Equipment Identification

12

MPS75 NT5C10C(X) power shelf (23-inch)

12

Helios Rectifier 25/48 NT5C06D(X) –48 V / 25 A Switch Mode Rectifier

13

Specifications

15

Electrical specifications

15

Output noise and ripple

16

Efficiency and Power Factor

16

Reliability

16

Heat Dissipation

16

Electromagnetic interference (EMI)

16

Environmental specifications

17

Operating

17

Transportation

17

Storage

17

Installation and start up

19

Tools and test equipment

19

Installing the power shelf

19

Wiring the power shelf

20

Installing the AC power

21

DC Conductors Installation

22

Control and Alarm Connections

23

Verification

28

Installing the rectifier

28

Factory setting

28

Rectifier meter accuracy

29

Start-up and verification

29

Slope Load Share

32

Helios Rectifier 25/48NT5C06D Installation and User Manual

Image 7
Contents P0831010 Standard 7.00 May Helios Rectifier 25/48 Single Phase -48V, 25 aPage Helios Rectifier 25/48 Single Phase -48V, 25A Page Publication history This page is left blank intentionally Contents Contents List of Tables List of ProceduresList of Figures ShelfThis page is left blank intentionally Description IntroductionApplications MPS75 NT5C10CX  power shelf 23-inchEquipment Identification MPS75 Modular Power Shelf-NT5C10C with 8-pin signal cables NT5C06D Switch Mode Rectifier Electrical specifications SpecificationsElectrical specifications Heat Dissipation Efficiency and Power FactorOutput noise and ripple ReliabilityTransportation Environmental specifications OperatingStorage Specifications Installing the power shelf Installation and start upTools and test equipment Procedure 1 Installing the power shelf Step Action Wiring the power shelfMax for each rectifier Installing the AC powerAC cable wire size AWG for each rectifierPower shelf individual AC connection DC Conductors InstallationConnecting the DC power shelf Control and Alarm ConnectionsRectifier 3 fail alarm Rectifier Failure AlarmRectifier 1 fail alarm Rectifier 2 fail alarmSense Fail AC Line Fail AlarmFan Alarm DC Circuit BreakerA0384387 SIG NAL Cables FRO M Shelves Factory setting Installing the rectifierVerification Rectifier meter accuracy Procedure 4 Starting up the rectifier StepHigh Voltage Shutdown Hvsd Adjustment Float Voltage Adjustment= 52.2 + .15 V = 52.35 Current Limit Verification CL Ii Forced ShareLoad Sharing Forced Load Share Load Share Adjustment ProcedureProcedure 5 Adjusting the load share Step Action Slope Load ShareOperation High voltage shutdown Hvsd local FeaturesFront panel controls Local float / equalize controlFan failure alarm Start-up delayIndicators Rectifier failure alarm RFARemote voltage sensing Sense fail alarm SEN FailLocal ON/OFF control AC breaker Remote ON/OFF controlParallel operation Sequential startDischarge of output capacitors Thermal shutdown Local / remote high voltage shutdown resetPower interface edge connector Input AC voltage monitorPower interface connections Signal interface connectorControl signal connections Procedure 6 Adjusting the float / equalize Step MaintenanceFloat / equalize Cooling fan High voltage shutdown HvsdFan failure Fan replacement NT5C06D rear view Power shelf This page is left blank intentionally Alarm indication RFA fault TroubleshootingSystem fault diagnosis Fault symptom Possible causes Fault symptom Possible causes SEN Fail faultErratic load fault Current or voltage float faultCPC Appendix a Replacement partsAppendix a Replacement parts Local toll-free prefixes Appendix B Technical service assistanceCountry Toll-free technical assistance numbers Appendix B Technical service assistanceUnited States Canada Europe Asia and the Pacific List of terms and acronyms Sense Fail Rectifier Fail AlarmNormally Open Northern TelecomPage Part of Emerson Network Power