5.2.10MON-B Monitor Display
The secondary monitor output, designated as the
The operator can either select
The
The sequence dwell times for the
5.2.11MON-B Button
Used to toggle the front panel control from
Fixed
The
5.2.12ARROW Buttons (MON-B)
Used to select a camera for display on the
Each arrow button is mapped to a quadrant on the screen, and will alternately select the two cameras associated with that quadrant.
5.2.13SEQ Button (MON-B)
Sequencing on the
To start sequencing while in the
The
The
To start/stop sequencing on the
5.3Alarm Input Operation
The product is equipped with 4 alarm inputs (TC8277 Series) or 8 alarm inputs (TC8278 Series), each associated with its corresponding video input. System action during an active alarm includes
The alarm inputs are configured as zero potential relay contacts, individually programmable via the menu to be normally open (NO) or normally closed (NC). Refer to the setup MENU to select the input configuration as NO or NC. Any alarm inputs can be enabled or disabled via the setup MENU.
Alarms may be cancelled (acknowledged) via a contact to ground on a rear panel input, or by pressing the SELECT button.
5.3.1Alarm Input Handling
There are three ways of handling alarms, which may be selected by the operator in the setup MENU.
5.3.2Latched Alarms
Alarms are latched as they become active. An alarm is cleared when the operator acknowledges it. There is no time out period.
Note: When the operator acknowledges (cancels) the alarm, it will be cleared whether the alarm input is still active or not.
Alarms that have been acknowledged by the operator will not be reactivated until the alarm input has ceased and then restarts.
5.3.3Timed-out (Captured) Alarms
Alarm inputs that are still active after the time out, become manual type alarms. Alarms that cease and restart before the time out is complete, will restart the time out period. Timed out alarms can be cleared by the operator before they time out. Alarms that are cleared before their inputs have ceased, will not be reactivated until the alarm input ceases and restarts.
5.3.4Manual Alarms (No Capture)
Alarms are active only while the alarm input is active. As soon as the alarm input ceases, the alarm is cleared.
5.3.5Clearing Alarms
Alarms are cleared by pressing SELECT/ALARM CLR, or by pulling a rear panel contact (pin 4) to ground. Refer to the rear panel drawing for the location of the contact.
10