Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA
Emergency Telephone: (800) 526-4371
MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Identity: | 5485 Toner | MSDS No. | CP- 339 |
Product ID: | Issued: | 04/20/2000 | |
|
| Supersedes: | None |
Synonyms |
| Date: | 04/20/2000 |
& Common |
| Prepared by: | EH&S Department |
Names: | Toner for Lanier 5485 | Approved by: | Larry Choskey, Manager, CEH&S |
|
| European | Walter Fricke, Manager, Safety & |
Uses: | Lanier 5485 | Contact: | Environment, |
|
|
| Lanier Worldwide, Inc. |
Chemical |
|
| Im Taubental D |
Formula: | Mixture |
| Germany |
Section 2: Composition / Information on Ingredients
| PERCENT | CAS No. | EXPOSURE LIMITS | SOURCE |
Polyester resin | 60 – 80 | Confidential | 8mg/m3 | ACGIH TWA |
Styrene acrylic polymer | 10 – 30 | Not listed | N/a | |
Carbon black | 7 – 15 | 3.5mg/m3 3.5mg/m3 | OSHA PEL ACGIH TWA | |
Wax | < 5 | Not listed | N/a | |
Dye | < 1 | Not listed | N/a |
*PEL as the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust)
*TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)
| Section 3: Hazards Identification |
HMIS Rating: |
|
FLAMMABILITY = 1 | HEALTH = 1 |
REACTIVITY = 0 | SPECIAL = none |
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non- toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner revealed there were no lung changes at all in the lowest exposure level (1mg/m3), the most relevant level to potential human exposures. A very slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m3), while a slight degree of fibrosis was observed at the highest exposure level (16mg/m3) in all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive amount of any dust retained in the lungs for a prolonged interval. The special test toner was ten times more respirable than commercially available toner to comply with EPA testing protocol and would not function properly in Xerographic equipment.
Carbon Black is listed on the IARC Monograph and the Massachusetts Substance List. The IARC has evaluated the evidence for the carcinogenicity of Carbon Black as inadequate to determine a carcinogenic risk for humans.
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200.
Section 4: First Aid Measures
| Remove to fresh air if effects occur. Get medical |
| In case of contact, immediately flush eyes with |
Inhalation: | attention if needed. | Eye Contact: | water for 15 minutes. Get medical attention if |
|
|
| needed. |
Skin Contact: | Wash with soap and water. | Ingestion: | Dilute stomach contents with several glasses |
|
|
| of water. Get medical attention. |
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO2, dry chemical, foam or water.
Extinguishing media which may not be used for safety reasons: none
This material will burn in case of fire. The decomposition products are CO, CO2, and Nox. Avoid inhalation of smoke. Special protective equipment for fire fighters: none
UEL: n/a | LEL: n/a |
|
|