DFCS XGT+ Standalone Module
SW3 and SW4 - RESERVED
These
2) INSTALL STANDALONE MODULE AND CONNECT CABLES
a.The XGT+ is available as a standalone module with
To power the unit using the AC/DC adapter, connect the AC/DC adapter to an AC outlet.
Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm
DC barrel connector
To power the unit using a DC power source, prepare a power cable using a two conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the unit by fastening the stripped ends to the DC power connector.
Connect the power wires to the DC power source. The Power LED should indicate the presence of power.
WARNING: Note the wire colors used in making the positive and negative connections. Use the same color assignment for the connection at the DC power source.
NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit.
b.Insert the appropriate 10G SFP+ or XFP transceiver (depending on the model of the module) into Port 1 receptacle on the XGT+. The release latch of the transceiver must be in the closed position before insertion.
c.Connect an appropriate multimode or
d.When using copper CX4 XFP, connect the cable between the converter and external device using the recommended copper CX4 cable.
e.Connect the
Page 6 |
|