Black Box LES404A, LES402A, LES401A manual Port Serial Server Terminal Block Pinout in RS-422 Mode

Page 57

Appendix B: RS-422/485 Connections

B.2 1-Port Serial Server Terminal Block Pinout in RS-422 Mode

Figure B-2. Terminal block connector.

Table B-2. 1-Port serial terminal block pinout

in RS-422 mode.

Signal Name

RS-422

RS-232

Terminal

 

 

 

 

Signal Ground

GND

1

 

 

 

 

Transmit Data (-)

TXD(-)

Out

2

 

 

 

 

Transmit Data (+)

TXD(+)

Out

3

 

 

 

 

Receive Data (+)

RXD(+)

In

4

 

 

 

 

Receive Data (-)

RXD(-)

In

5

 

 

 

 

In the RS-422 mode, TXD lines are outputs and RXD lines are inputs. Connect the Serial Server TXDB(+) line to the RXDB(+) line of the serial device, and the Serial Server TXDA(-) to the RXDA(-) of the serial device.

If flow control is set for RTS/CTS, connect the Serial Server RTSB(+) to CTSB(+) of the serial device and the Serial Server RTSA(-) line to the CTSA(-) of the serial device. Connect from the Serial Server CTSB(+) line to the RTSB(+) of the serial device and from the Serial Server CTSA(-) line to the RTSB(+) line of the serial device.

If connecting to receive-only RS-422 devices, connect from the Serial Server TXDB(+) and TXDA(-) lines to the receive pairs on all serial devices.

Ground is signal ground and provides a common mode reference for the RS-422 receiver and transmitters.

724-746-5500 blackbox.com

Page 57

Image 57
Contents 4-Port Industrial Ethernet Serial Servers Trademarks Used in this Manual Trademarks Used in this ManualFCC and NOM Statement NOM Statement Table of Contents Using Telnet Software Installation Hardware SetupSerial Server Configuration Quick Start GuideFigure QS-3. Configuring the Virtual COM Port Install Virtual COM Ports on PCCheck Communications Specifications General SpecificationsDefault Settings Port Serial Server dimensions Overview 2-, and 4-Port Industrial Serial Servers FeaturesDirect IP Mode Virtual COM ModeCommunication Modes Heartbeat Paired ModeWhat’s Included Hardware DescriptionShows the 2-Port Serial Server. -2 describes its components Overview Hardware Configuration SwitchesConnectors Console Mode Default ModeUpgrade Mode Serial Server/Port Operational Modes5 RS-422 Mode 4 RS-232 Mode6 RS-485H Mode 7 RS-485F ModePort Industrial Serial Server bias jumpers J13 Pull up Pull down Half-duplex 422/485 full-duplex J20 Installing the Software Installing the SoftwareAutomatic Installation Manual InstallationInstalling the Software Opening the Serial Server Manager software Updating an Existing InstallationUsing Serial Server Manager Using Serial Server ManagerSerial Server Manager window Software SetupMenus Software OverviewServer Icons Pane Serial Server/Virtual COM ListsSearch for Servers Server Properties window Configure Server PropertiesConfiguring the Serial Server Properties Configuring the Serial Server PropertiesDhcp Configuring the Serial Server Properties Configuring the Serial Server Properties Configuring the Serial Server Properties Configuring the Serial Server Properties Installing Virtual COM Ports Installiing Virtual COM PortsVirtual COM Port Installation COMInst window Matching the Serial Server and Virtual COM Port Settings Installing Virtual COM Ports Removing Virtual COM Ports Using Serial Server Manager Using Device ManagerRemoving Virtual COM Ports Removing Virtual COM Ports Removing Virtual COM Ports Upgrading the Serial Server Firmware Preparing the SoftwareUpgrading the Firmware Upgrading the Serial Server Firmware Using Console Mode Using Console ModeConsole Mode Setup Navigating the Configuration MenusConsole Mode Configuration screens Using Console Mode Using the Web Server Using the Web ServerUsing the Web Server Web Server Operation Using Telnet Using TelnetUsing Telnet Appendix a RS-232 Connections 1-Port Serial Server Terminal Block Pinout in RS-232 ModeAppendix B RS-422/485 Connections 1-Port Serial Server Terminal Block Pinout in RS-422 Mode Appendix C RS-485 Connections Signal Name RS-422 Direction Terminal Signal Ground Appendix D Network Connections Crossover Ethernet Cable RJ-45 Pinout Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7
Related manuals
Manual 2 pages 26.41 Kb

LES402A, LES401A, LES404A, 1-, 2-, and 4-Port Industrial Ethernet Serial Servers specifications

The Black Box LES402A, LES404A, and LES401A are robust industrial Ethernet serial servers designed to facilitate seamless communication between serial devices and Ethernet networks. These devices come in various configurations, including 1-port, 2-port, and 4-port options, making them suitable for a wide range of applications.

One of the primary features of the Black Box LES series is their ability to convert asynchronous serial data into a TCP/IP format. This functionality allows legacy devices to be integrated into modern Ethernet networks, providing businesses with a cost-effective solution to modernizing their infrastructure without replacing existing equipment. The devices support various serial protocols, including RS-232, RS-422, and RS-485, ensuring compatibility with numerous devices.

Each server in this series is equipped with advanced features such as selectable baud rates, which range from 300 to 921,600 bps, catering to the needs of diverse serial peripherals. Additionally, the LES402A, LES404A, and LES401A include an easy-to-use web-based management interface that simplifies configuration and monitoring. Users can quickly set up parameters, manage connections, and perform diagnostics, all from a centralized interface.

Robustness and reliability are crucial for industrial applications, and the Black Box LES series does not disappoint. Built to withstand harsh environments, these devices feature a rugged metal housing that protects against dust, moisture, and other environmental factors. Additionally, they come with Ethernet port support for Auto-MDIX, simplifying cable connections by automatically detecting and adjusting the port configuration.

Security is another significant consideration. The Black Box LES servers include features such as SSL and SSH support that secure data transmission between devices, making them suitable for sensitive applications. Furthermore, the devices support SNMP for network management, allowing for remote monitoring and management.

In summary, the Black Box LES402A, LES404A, and LES401A series of Industrial Ethernet Serial Servers are designed to bridge the gap between legacy serial devices and modern Ethernet networks. With their robust construction, varied port options, and advanced features, these devices enhance connectivity and streamline operations in demanding industrial environments. Their flexible configuration and security protocols make them a reliable choice for organizations looking to integrate their legacy systems into contemporary networks.