© Copyright 2011. All rights reserved.
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Bluetooth is a registered trademark of The Bluetooth SIG, Inc.Any other trademarks mentioned in this manual are acknowleged to be the property of the trademark owners.
4. Description of LED Functions |
|
| |
|
| Table 1. LEDs and their functions. | |
LED | State | Function | Description |
ON, CONNECT, | All three LEDS light | Power up | Upon |
FAULT LEDs |
|
| part of the |
ON LED | Lights green after | DC output | After two seconds, the ON LED will light green, indicating that |
| two seconds | voltage available | the DC output voltage is available for powering an 802.3af |
|
|
| PoE compliant load. |
CONNECT | Lights green | 802.3af load | This green LED lights when a compliant load is attached to |
LED |
| is attached | the output |
| Blinking | 802.3af load | If the load does not comply with 802.3af PoE standards, |
|
| is not attached | then the LEDs will blink a code indicating that the load was not |
|
|
| detected. See Table 2 for code descriptions. |
FAULT LED | Lights red | Overload or |
|
| short circuit |
| Lights red for | Power supply is |
| two seconds, | trying to |
| then goes off | a valid load |
If a fault, such as an overload or short circuit, occurs, then the red FAULT LED lights. See Table 2 for code descriptions.
The red LED will light for two seconds and then go off as the power supply tries to
802.3af PoE load is NOT detected, the LED will indicate the problem as described in Table 2.
| Table 2. Failure detection codes. | |
Code | Name | Description |
1 | Incorrect resistive signature | The green CONNECT and red FAULT LEDs blink three times. |
2 | Incorrect capacitive signature | The green ON LED blinks three times. |
3 | Incorrect V offset | The green CONNECT and green ON LEDs blink three times. |
4 | Unstable current measurement | The green ON LED blinks three times. |
5 | Low voltage sensed during detection (overload) | The red FAULT LED blinks three times. |
NOTE: After the LEDs blink three times, the power injector will continue to try to detect a valid load. Until the correct load is applied, the LEDs will continue to blink. If an open circuit is connected to the output
FREE, live, 24/7 Tech Support is just 20 seconds away.