PRODUCT: 3107 | PSDS No. 0614 |
Floor Space Requirements | Weight |
(Meter / Feet) | (K Grams / Lbs.) |
1.4 X 1.7 / 4.6 X 5.6 | 146 / 322 |
Section V - Emission/Exposure Information* |
|
Light Source |
|
Long Term Viewing of Exposure Lamp May Be Uncomfortable But Not Harmful
Electromagnetic Emissions
FCC: Class A
DOC: Class A
Audible Noise | TLV | |
Run | 57.2 dB (A) | 85 dB (A) |
Impulse | 71.3 dB (A) |
|
Ozone |
| TLV |
422 ug/min |
| 0.1 ppm |
0.038 ppm (TWA) |
| |
0.082 ppm (Peak) |
| |
Concentration Based on Customer Simulation Model: | ||
Daily Copy Volume | 898 copies/7.88 hours | |
Room Size |
| 7.01m3 |
1/2 Air Room Change per Hour |
| |
Total Dust |
| TLV |
Total 0.06 mg/m3 | 10 mg/m3 | |
Selenium |
| TLV |
200 ug/m3 | ||
Arsenic |
| PEL |
| 10 ug/m3 |
*Time weighted average (TWA) for normal, eight hour workday. TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposures permitted to ensure no health hazard.
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.
www.xerox.com Reference “About Xerox”