Xerox 3107 manual Product, Tlv, Pel

Page 2

PRODUCT: 3107

PSDS No. 0614

Floor Space Requirements

Weight

(Meter / Feet)

(K Grams / Lbs.)

1.4 X 1.7 / 4.6 X 5.6

146 / 322

Section V - Emission/Exposure Information*

 

Light Source

 

Long Term Viewing of Exposure Lamp May Be Uncomfortable But Not Harmful

Electromagnetic Emissions

FCC: Class A

DOC: Class A

Audible Noise

TLV

Run

57.2 dB (A)

85 dB (A)

Impulse

71.3 dB (A)

 

Ozone

 

TLV

422 ug/min

 

0.1 ppm

0.038 ppm (TWA)

 

0.082 ppm (Peak)

 

Concentration Based on Customer Simulation Model:

Daily Copy Volume

898 copies/7.88 hours

Room Size

 

7.01m3

1/2 Air Room Change per Hour

 

Total Dust

 

TLV

Total 0.06 mg/m3

10 mg/m3

Selenium

 

TLV

0.04-0.07 ug/m3

200 ug/m3

Arsenic

 

PEL

0-0.03 ug/m3

10 ug/m3

*Time weighted average (TWA) for normal, eight hour workday. TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposures permitted to ensure no health hazard.

All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.

www.xerox.com Reference “About Xerox”

Image 2
Contents Xerox BTU/HRPEL ProductTLV