SAFETY INSTRUCTIONS

Read the safety and operating instructions before operating the apparatus.

Retain safety and operating instructions for future reference.

Adhere to all warnings on the apparatus and in the operating instructions manual.

Follow all instructions for operation and use.

This apparatus conforms to: CE, IEC 60950,

UL 60950, CAN/CSA C22.2 No. 950-95 (cUL)

Usage in Hazardous locations

Class I equipment

Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.

FCC notice

This equipment has been tested and found to comply with the limits of a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Power connection

Power requirements: The apparatus must be powered using the 12 VDC power supply that is supplied with the apparatus. The 12 VDC power supply must be powered by the AC mains voltage.

• Power cord with CEE 7 plug (): The colors of the mains lead are colored in accordance with the following code: Green-and-yellow: Earth (safety earth), Blue: Neutral, Brown: Line

Power cord with ANSI 73.11 plug (): The wires of the power cord are colored in accordance with the following code: Green/ yellow: ground, White: neutral, Black: line (live)

Power requirements: connect the apparatus to an AC voltage as indicated at its back. Using a lower voltage, the apparatus will not be able to operate. Using a higher voltage may damage the apparatus. If you are not sure of the type of power supplied, consult the power company.

Do not overload wall outlets and extension cords as this may result in fire or electric shock.

Mains lead protection (U.S.: Power cord): Supply cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles.

Water and moisture

Never expose the apparatus to rain or moisture.

Never use the apparatus near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or in a wet basement.

Ventilation

Do not cover or block the ventilation openings in the cover of the set. When installing the apparatus in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard.

Installation

Place the apparatus on a flat, solid and stable surface that can bear the weight of at least 3 monitors. If you use an unstable cart or stand, the set may fall, causing serious injury to a child or adult, and serious damage to the equipment.

More warnings in the Installation chapter.

User manual MFGD 2320

3

Image 4
Contents Mfgd Contents Page Safety Instructions Usage in Hazardous locationsAutoset feature OverviewIntroduction GuardPackage contents Front Controls and connectorsSide Rear Precautions InstallationBefore installing the display Connecting the signals Portrait or landscape positionTo connect analog video & sync signals on BNC Routing the signal cables Using the USB hub Tilt and swivel positioningStarting up To use the USB hubSwitching to stand-by position OperationControlling the display About the on-screen menusSaving changes Using the Autoset* functions When do you need to use the Autoset functions?Required test pattern To enter the Autoset menuAutoset menu contains the following items Controlling Video Contrast* and Video BrightnessTo enter the menu To select the calibrated position To change Video Contrast or Video Brightness manuallyAdditional information Making adjustments Setting the Luminance valueHow to make the adjustments? Click the control wheel. The Adjustments menu appears Phase adjustments Phase menu contains the following itemsSelecting inputs To enter the Inputs menuYou can select the following input selection settings SettingsTo enter the Settings menu Settings menu contains the following items Scan ModeTo enter the Scan Mode menu Getting information Scan Mode menu contains the following itemsTo enter the Information menu General Information menu contains the following items Advanced Functions About this chapterAbout the Advanced functions To log in as advanced userAmbient Light Compensation Advanced functions in the Adjustments menuLow Pass Filter Advanced functions in the Settings menu Input ModeStandard input mode Lookup TableExtended input mode GRB-YAdvanced functions in the Scan Mode menu Reset AllService Advanced functions in the Information menuMaintenance Windows does not show the desired display settings Cleaning instructionsTroubleshoot ING To remove the glass panelTechnical Specifications Pixel FaultsResolution GeneralLuminance VideoPower consumption Power sourceSync Approvals

MFGD 2320 specifications

The Barco MFGD 2320 is a cutting-edge display solution specifically designed for the demanding requirements of medical imaging and diagnostic applications. With a focus on providing high image quality and precision, the MFGD 2320 is ideal for radiology, mammography, and other specialized medical fields.

One of the main features of the MFGD 2320 is its impressive 32-inch display size, which offers ample screen real estate for detailed medical images and data. The monitor boasts a resolution of 2 MP (1920 x 1080), ensuring sharp, clear images that allow medical professionals to make accurate diagnoses. The display utilizes a high-quality LCD panel that supports a wide color gamut, providing vibrant and true-to-life colors essential for medical applications.

The MFGD 2320 is equipped with Barco's proprietary MediCal QAWeb technology, which is integral for maintaining consistent image quality over time. This automated software allows for the calibration and quality assurance of the display, ensuring compliance with stringent medical imaging standards. MediCal QAWeb also helps minimize downtime by providing remote monitoring capabilities, enabling technicians to address any issues proactively.

Additionally, the monitor's ergonomic design is another significant characteristic. The MFGD 2320 features a sleek, lightweight form factor that can be easily integrated into various clinical environments. It offers adjustable height and tilt options, allowing for optimal viewing angles for healthcare professionals. The anti-glare coating on the screen reduces reflections, further enhancing visibility during critical diagnostic tasks.

In terms of connectivity, the Barco MFGD 2320 offers multiple input options, including DisplayPort and DVI, making it compatible with various imaging systems and workstations. This flexibility allows for seamless integration into existing setups without the need for extensive modifications.

Another standout technology of the MFGD 2320 is its low blue light emission feature, which helps reduce eye strain and fatigue, essential for professionals who spend long hours in front of the screen. This focus on user comfort, combined with its exceptional image performance, makes the MFGD 2320 an ideal choice for healthcare environments where reliability and precision are paramount.

In summary, the Barco MFGD 2320 is a versatile, high-performance display tailored for the medical imaging sector. Its combination of large screen size, superior resolution, advanced calibration technology, and ergonomic design makes it a valuable asset for healthcare professionals striving for excellence in patient care and diagnosis.