TRENDnet TPL407E2K manual Technical Specifications

Page 25

TRENDnet User’s GuideTPL-407E / TPL-407E2K

 

Technical Specifications

 

 

 

 

 

 

 

 

 

 

Powerline (PL) Connection

 

 

 

 

 

 

Green (Best)

 

 

Hardware

 

 

 

 

 

 

 

 

Amber (Better)

 

 

 

 

 

 

 

 

Standards

IEEE 1901, HomePlug® AV, IEEE 802.3, IEEE 802.3x, IEEE 802.3u

 

 

Red (Good)

 

 

 

 

 

 

Off (No connection)

 

 

Interface

1 x 10/100 Mbps Auto-MDIX RJ-45 port

 

 

 

 

 

 

 

 

 

 

 

1 x built-in electrical power socket with noise filtering

 

 

 

 

 

 

 

o A: North America Type B (NEMA 5–15) (15A max.

 

 

Ethernet (ETH) Connection

 

 

 

@ 120VAC)

 

 

Solid (connection)

 

 

 

o EU: European Type F (CEE 7/7) (16A max. @

 

 

 

 

 

 

 

Blinking (activity)

 

 

 

250VAC)

 

 

Off (no connection)

 

 

 

o FEU/FR: French Type E (CEE 7/7) (16A max. @

 

 

 

 

 

 

Buttons

Sync (3 sec.) / Reset (20 sec.)

 

 

 

250VAC)

 

 

 

 

o UK : United Kingdom Type G (BS 1363) (13A max.

 

Dimension (L x W X H)

A: 78 x 55 x 59 mm (3.07 x 2.17 x 2.32 in.) per unit

 

 

 

@ 250VAC)

 

 

EU: 78 x 55 x 77 mm (3.07 x 2.17 x 3.03 in.) per unit

 

 

 

1 x Sync / reset button

 

 

 

 

 

 

 

FEU/FR: 78 x 55 x 75 mm (3.07 x 2.17 x 2.95 in.) per unit

 

 

 

Power prong

 

 

 

 

 

o A: North America Type B (NEMA 5–15)

 

 

UK: 78 x 55 x 68 mm (3.07 x 2.17 x 2.68 in.) per unit

 

 

 

o EU: European Type E/F Hybrid (CEE 7/7)

 

 

 

 

 

 

 

Weight

A: 102 g (3.6 oz) per unit

 

 

 

o FEU/FR: French Type E/F Hybrid (CEE 7/7)

 

 

EU: 138 g (4.87 oz) per unit

 

 

 

o UK : United Kingdom Type G (BS 1363)

 

 

 

 

Frequency Band

2 ~ 68 MHz

 

 

FEU/FR: 138 g (4.87 oz) per unit

 

 

 

 

 

 

UK: 134 g (4.73 oz) per unit

 

 

Modulation

OFDM Symbol Modulation on link synchronization,

 

 

 

 

 

 

 

 

 

 

 

1024/256/64/8 - QAM, QPSK, BPSK, ROBO Carrier

 

Power Source

100~250V AC, 50~60Hz

 

 

 

 

 

 

 

 

 

Protocol

TDMA and CSMA/CA

 

Consumption

Active mode: 3 Watts (max.)

 

 

 

 

 

 

Standby mode: 0.5 Watts (max.)

 

 

Speed

Powerline: up to 500 Mbps**

 

 

 

 

 

 

 

 

 

 

 

Ethernet: Up to 200 Mbps (Full Duplex mode)

 

Temperature

Operating: 0° ~ 40°C (32° ~ 104°F)

 

 

 

 

 

 

Storage: -10° ~ 55°C (14° ~ 131°F)

 

 

Utility OS Compatibility

Windows 7 (32/64-bit), Vista (32/64-bit), XP (32/64-bit)

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

Max. 95% (non-condensing)

 

 

Nodes

Up to 8 (max.)

 

 

 

 

 

 

 

 

 

 

 

 

Certifications

CE, FCC

 

 

 

Overlapping

Up to 4 (per electrical system)

 

 

 

 

 

 

 

 

 

 

Powerline Networks

 

 

* Maximum of 8 adapters (nodes) recommended for streaming video across your network.

 

 

 

 

 

** 500Mbps is the maximum theoretical Powerline data rate. Actual throughput will vary

 

 

Coverage

Up to 300 m (984 ft.)

 

 

 

depending on environment.

 

 

 

 

 

 

 

 

 

 

 

Security

128-Bit AES (Advanced Encryption Standard)

 

 

 

 

 

*** Networked Powerline devices need to be plugged into power outlets that are on the same

 

 

LED

Power (PWR)

 

electrical system.

 

 

 

 

 

**** GFCI outlets and AFCI circuit breakers may degrade Powerline network signals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© Copyright 2012 TRENDnet. All Rights Reserved.

 

 

 

23

 

 

 

 

 

 

 

 

Image 25
Contents Page Contents Features TPL-407ETPL-407E2K Package ContentsProduct Overview Ethernet Port Power Prong Sync/Reset Button Product Hardware FeaturesDevice Label Color Sequence Definition ResetButton Action Function SyncApplication Diagram Before you Install Installing your Powerline AdaptersConnect a Powerline adapter to your router Add adapters to your network To extend your network using an additional Powerline adapterUsing the Sync button Securing your Powerline NetworkChange your default encryption key using the Sync button TRENDnet User’s Guide Add adapters using the Sync button TPL-401E /TPL-402E /TPL-405E adapter you add to your network Powerline Utility System Requirements Using the Powerline UtilityTRENDnet User’s Guide TRENDnet User’s Guide Before using the utility, please ensure the following Using the UtilityDevice Name Device Password Connection Speed or Powerline Utility OverviewQuality Link Rate Rename Enter Password Upgrade FirmwareEncryption Key Use Default Public NetworkSet Local Device Only Set All Devices Remote Device History Log System InformationReport AutoScan UXMA-UOUP-IQXJ-UTYN Click Enter PasswordTPL-407E / TPL-407E2K To rename the Powerline adapters TRENDnet User’s Guide Technical Specifications Troubleshooting Appendix Overlapping Powerline networksFCC Radiation Exposure Statement Federal Communication Commission Interference StatementRoHS Europe EU Declaration of ConformityΜΕ ΤΗΝ Παρουσα TRENDnet Δηλωνει ΟΤΙ TPL-407E Limited Warranty