Troubleshooting Reference
WARNING: Electric shock hazard
Do not remove the cover of the XADC or disassemble the XADC. The XADC does not contain any internal
Table | Troubleshooting reference |
|
| |
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
|
|
XADC will |
| Cables are loose |
| Check DC and AC connections |
not run |
| Output fuses are |
| Check output fuses |
|
|
| ||
|
| damaged or not |
|
|
|
| installed |
|
|
|
| AC input breaker open |
| Check AC input breaker |
|
| Short circuit in one or |
| Remove load fuses one by one until |
|
| more of the load |
| XADC output voltage recovers, |
|
| circuits |
| |
|
|
|
| find faulty load circuit(s) |
|
| Internal temperature |
| Check that the XADC has sufficient |
|
| too hot |
| ventilation. Allow the XADC to cool |
|
|
|
| down and restart. |
|
| Something may be |
| Ensure that nothing is obstructing |
|
| preventing the fan |
| the fan operation. |
|
| from turning. The unit |
|
|
|
| has a safety shutoff in |
|
|
|
| this situation. |
|
|
|
|
|
|
|
6 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|