Technical Specifications
For use with Transition Networks Model
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
Compliance | UL listed EN60950; FCC & CISPR class A; CE Mark | |
Dimensions | ||
(length x width x height) | ||
| ||
| ||
Power Distribution | 12.6 VDC at 1.0 A maximum | |
Power Consumption | 6 W maximum @ 18 VDC input, 12.6 W output | |
Efficiency | 70 % (typical) |
|
Noise and Ripple | ± 40 mV | |
MTBF | >290,000 hours Belcore with typical load at 50°C | |
| ambient temperature (calculated according to Belcore). | |
| >834,000 hours with typical load at 50°C ambient | |
| temperature (calculated according to | |
Environment | Tmra*: | 0 to 50°C (32 to 122° F ) |
| Storage Temp: | |
| Humidity: | 5 to 95%, non condensing |
| Altitude: | 0 to 10,000 feet |
| (*Manufacturer’s rated ambient temperature) | |
Warranty | Lifetime |
|
Technical Specifications
Input:
Input Voltage | 18 - 60 VDC, 24 - 30 VRMS |
Isolation Voltage | (Dielectric withstand) Meets IEC 950 for one minute |
| 1500 VAC: Output/Input |
| 1500 VAC: Input/Safety GND |
| 1500 VAC: Output/Case |
Output: |
|
Output Voltage | 12.6 VDC |
Output Current | 1.0 A |
Load Regulation | ±5% at 10% load to |
Over Load Protection | (OLP) When the average power rating exceeds 125%- |
| 150% of the maximum power, the output voltage is |
| reduced to a safe dissipation level. This action protects |
| against output short circuit. |
No Load Operation | No damage to power supply when operating at no load. |
Transient Protection | No voltage spike at |
| failure. |