E
System configurator and
PRIMERGY T850 | Status |
Section VII
SCSI/Fibre Channel Controller
Inclusive
The 2nd channel of the Dual-
Included in the basic and system units.
The two HD SCSI drives are connected to one
4x
Controller for the connection of an external storage system:
|
|
|
| not released for | |
|
|
|
| ||
SCSI 160 controller |
|
|
|
| VMware ESX Server |
Adaptec SCSI card 29160
1 channel: LVD+Fast/Ultra (decoup.) LVD con. for HD, withoud cable Fast/Ultra con. access. drives
64/66 (32/33) PCI, min. 180mm
int: Fast
+LVD HD68; ext: HD68(LVD) SW:
max. 2x per system
Fibre Channel controller for subsystems and SAN
| while | stocks last |
| while | stocks last |
| |||||
|
|
|
|
| |||||||
| 1GBit/s FC Controller |
|
| 1GBit/s FC Controller |
|
| |||||
| Qlogic |
|
| Qlogic |
|
|
| ||||
| QLA 2200 |
|
| QLA 2200F |
|
|
| ||||
| 1 Channel 1GBit/sec FC Controller |
|
| 1 Channel 1GBit/sec FC Controller |
|
| |||||
| CU (copper) Interface |
|
| MMF(Multimode Fibre) Interface |
|
| |||||
| incl. SW and description (Ger/US) |
|
| incl. SW and description (Ger/US) |
|
| |||||
| PCI 64Bit / 66MHz, 175mm |
|
| PCI 64Bit / 66MHz, 175mm |
|
| |||||
| 3.3V and 5V tolerant signaling |
|
| 3.3V and 5V tolerant signaling |
|
| |||||
| max. 4x per system |
|
| max. 4x per system |
|
|
| ||||
|
|
|
|
|
|
|
|
| while | stocks last | |
|
|
|
|
|
| ||||||
|
|
| 2GBit/s FC Controller |
|
| 2GBit/s FC Controller | |||||
|
|
| Emulex |
|
|
| Emulex | ||||
|
|
| LP9802 |
|
|
| LP9002L | ||||
|
|
| 1 Cannel 2GBit/sec FC Controller |
|
| 1 Channel 2GBit/sec FC Controller | |||||
|
|
| LC Interface for 50um Fiber |
|
| LC Interface for 50um Fibre | |||||
|
|
| PCI 64Bit / 133MHz, 170mm |
|
| PCI 64Bit / 66MHz, 170mm | |||||
|
|
| 3.3V and 5V tolerant signaling |
|
| 3.3V and 5V tolerant signaling | |||||
|
|
| max. 4x per system |
|
|
| max. 4x per system | ||||
|
|
|
|
|
|
|
|
|
|
|
|
Attention
2GBit/s FC Controller require other interface connectors for the optical cables than 1GBit/s fibre channel.
There are other components such as switches, GBICs or cables which can be ordered for fibre channel SAN attachments. (see price list)
All controllers for the connection of external storage systems are delivered without cables.
For the configuration of external cabling see the configurator for external storage systems.
All internal cables and adapters are included within the basic units and components respectively.
F
Fujitsu Siemens Computers | 10 of 18 |
Enterprise Products - PRIMERGY Server |