IBM 8172 manual Turn on CD when remote carrier is present

Page 57

￿￿￿

 

￿￿

 

 

 

 

X4

All responses and dial tone and busy signal

 

 

detection

 

 

 

Z_

Z0

Reset and retrieve active profile 0

 

 

 

 

Z1

Reset and retrieve active profile 1

 

 

 

￿￿ AT ￿￿￿

￿￿￿

 

￿￿

 

 

 

&C_

&C0

Force Carrier Detect Signal High (ON)

 

 

 

 

&C1

Turn on CD when remote carrier is present

 

 

 

&D_

&D0

Modem ignores the DTR signal

 

 

 

 

&D1

Modem returns to Command Mode after DTR

 

 

toggle

 

 

 

 

&D2

Modem hangs up, returns to the Command

 

 

Mode after DTR toggle

 

 

 

 

&D3

Resets modem after DTR toggle

 

 

 

&F_

&F

Recall factory default configuration

 

 

 

&G_

&G0

Guard tone disabled

 

 

 

 

&G1

Guard tone disabled

 

 

 

 

&G2

1800 Hz guard tone

 

 

 

&K_

&K0

Disable flow control

 

 

 

 

&K3

Enable RTS/CTS hardware flow control

 

 

 

 

&K4

Enable XON/XOFF software flow control

 

 

 

 

&K5

Enable transparent XON/XOFF flow control

 

 

 

 

&K6

Enable both RTS/CTS and XON/XOFF flow

 

 

control

 

 

 

&M_

&M0

Asynchronous operation

 

 

 

&P_

&P0

US setting for off-hook-to-on-hook ratio

 

 

 

 

&P1

UK and Hong Kong off-hook-to-on-hook ratio

 

 

 

 

&P2

Same as &P0 setting but at 20 pulses per minute

 

 

 

 

&P3

Same as &P1 setting but at 20 pulses per minute

 

 

 

&R_

&R0

Reserved

 

 

 

 

&R1

CTS operates per flow control requirements

 

 

 

&S_

&S0

Force DSR Signal High (ON)

 

 

 

 

&S1

DSR off in command mode, on in on-line mode

 

 

 

&T_

&T0

Ends test in progress

 

 

 

 

&T1

Perform Local Analog Loopback Test

 

 

 

 

&T3

Perform Local Digital Loopback Test

 

 

 

 

&T4

Grant Remote Digital Loopback Test request by

 

 

remote modem

 

 

 

 

&T5

Deny Remote Digital Loopback Test request

 

 

 

￿￿ C. ￿￿ ￿￿ ￿￿￿ 41

Image 57
Contents 8424, 8425 8171, 8172 Page 8424, 8425 8171, 8172 47 D Iii Page IBM CRU Customer Replaceable Units . IBM UPS 80% IBM , IBM CD-ROM/DVD Page 33F8354 IBM Consignes de sécurité relatives au modem Xiii Xiv → Access IBM WWW Quick Path , Go Post PCI Watt 50/60 Hz USB Dimm 80% Page Page PCI 6 USB Readme Page 5 CMOS/BIOS PCI PCI , PCI Sata IDE 10 GB DIMMdual inline memory modue PCI PCI , PCI Express Cmos PCI PCI IBM Setup Utility 1 Master/slave 1 Bolt Mm U-bolt IBM Cmos 27 3 IBM Setup Utility Page IBM Setup Utility User Password IDE Drive User PasswordIDE Security Profile by Device Advanced Page POST/BIOS POST/BIOS POST/BIOS CMOS/BIOS Page DSP 1 2 4 3 ATH Enter Low speaker volume Turn on CD when remote carrier is present MNP/V.42/V.42bis/V.44 Fax Class +FHNG Taxsignal On Swisscom Page IBM , IBM IBM . IBM IBM Profile by device POST/BIOS Iso Page