Leadership enterprise server with significantly lower cost of ownership in a highly available and expandable,
replacing the older parallel PCI and
There is a
Dual Gigabit Ethernet Controllers
The x3550 M2 includes two integrated Broadcom 5709 Gigabit Ethernet controllers for up to
10X higher maximum throughput than a 10/100 Ethernet controller, as well as support for Jumbo Frames and TOE (TCP Offload Engine).
Jumbo
It also supports highly secure remote power management using IPMI 2.0, plus Wake on LAN® and PXE (Preboot Execution Environment) flash interface. Optional PCI adapters offering failover and load balancing between adapters are available for added throughput and increased system availability.
Integrated Quad GbE Ports via Broadcom 5709 GbE Controller.
•Up to four (4) GbE ports ideal for virtualization and I/O intensive workloads
•2 ports standard plus two additional ports optional via adapter card
•Improves system performance by offloading protocol processing from CPU to a separate TOE engine
•Primary performance improvement for data copying (CPU) where CPU utilization is
•The embedded NIC/TOE supports software iSCSI using a Microsoft iSCSI initiator
•Using a software initiator enables offloading the processing of TCP frames with the TOE engine in the adapter card but the processing of iSCI packets themselves is not hardware offloaded at the Broadcom NIC
•Broadcom hardware offloaded iSCSI (using TOE engine) of the iSCSI frames
•iSCSI and RDMA are not supported
Two Broadcom 5709 Gigabit Ethernet Controllers (one
Ultra-Efficient Cooling
Strategically located fans, combined with efficient airflow paths, provide highly effective system cooling for the x3550 M2, known as Calibrated Vectored Cooling. The base server with one power supply includes six
The system contains three cooling zones. Zone 1 (incorporating two fan packs) cools all 16 DIMM sockets, Zone 2 (two fan packs) cools the primary processor, and Zone 3 (one or two fan packs) cools the second processor (if installed).
The fans automatically adjust speeds in response to changing thermal requirements depending on the zone and internal temperatures. When the temperature inside the server increases, the fans speed up to maintain the proper ambient temperature. When the temperature returns to a normal operating level, the fans return to their default speed. In addition, the Bosch BMP085 altimeter works in conjunction with IMM to govern fan rotation. At high altitudes the air is thinner
7Actual throughput will depend on the adapter vendor’s implementation.
Please see the Legal Information section for important notices and information.