Cisco Systems OL-7765-04 manual Verifying the Module Status

Page 9
Verifying the Module Status

Chapter 2 Initial Switch Configuration

Verifying the Module Status

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m

Verifying the Module Status

Before you proceed with further configuration of the switch, ensure that the modules in the chassis are functioning as designed. To verify the status of a module at any time, issue the show module command. All the hardware that was physically installed should be displayed.

A sample output of the show module command follows:

switch# show module

 

 

Mod Ports Module-Type

Model

Status

-------- -------------------------------- ------------------ ------------

2

32

1/2 Gbps

FC Module

DS-X9032

ok

3

16

1/2 Gbps

FC Module

DS-X9016

ok

4

8

IP Storage Services Module

DS-X9308-SMIP

ok

5

0

Supervisor/Fabric-1

DS-X9530-SF1-K9

active *

6

0

Supervisor/Fabric-1

DS-X9530-SF1-K9

ha-standby

7

0

Caching Services Module

DS-X9560-SMAP

ok

9

32

Advanced

Services Module

DS-X9032-SMV

ok

Mod

Sw

Hw

World-Wide-Name(s)

(WWN)

 

-------------- ------ --------------------------------------------------

2

2.1(1a)

1.1

20:41:00:05:30:00:86:9e to 20:60:00:05:30:00:86:9e

3

2.1(1a)

3.0

20:81:00:05:30:00:86:9e to 20:90:00:05:30:00:86:9e

4

2.1(1a)

4.0

20:c1:00:05:30:00:86:9e to 20:c8:00:05:30:00:86:9e

5

2.1(1a)

4.0

--

6

2.1(1a)

4.0

--

7

2.1(1a)

0.702

--

9

2.1(1a)

0.502

22:01:00:05:30:00:86:9e to 22:20:00:05:30:00:86:9e

Mod

Application Image Description

Application Image Version

-------- -----------------------------

-------------------------

7

svc-node1

1.3(5m)

7

svc-node2

1.3(5m)

9

SSI linecard image

2.1(1)

Mod

MAC-Address(es)

Serial-Num

----------------------------------------- ----------

2 00-0c-30-d9-eb-60 to 00-0c-30-d9-eb-64 JAB074704EJ

3 00-0c-30-0d-27-54 to 00-0c-30-0d-27-58 JAB074004RR

4 00-0c-30-da-92-88 to 00-0c-30-da-92-94 JAB075204ZN

5 00-0c-30-d9-dc-d0 to 00-0c-30-d9-dc-d4 JAB074504RC

6 00-0c-30-d9-ef-80 to 00-0c-30-d9-ef-84 JAB0747055Y

7 00-0d-bc-2f-bc-b8 to 00-0d-bc-2f-bd-3c JAB073907DK

9 00-05-30-00-ad-4e to 00-05-30-00-ad-52 JAB070605QV

* this terminal session

Note If you do not see all the installed hardware, contact your storage vendor support organization for further assistance.

Cisco MDS 9000 Family Fabric Manager Quick Configuration Guide

 

OL-7765-04

2-9

 

 

 

Image 9
Contents Preparing for Network Connections Configuration PrerequisitesInitial Switch Configuration Connecting the Console Port, pageConnecting the Console Port MGMT 10/100 CONSOLEConnecting the Console Port to a PC Connecting the 10/100 Ethernet Management PortUsing the Switch Setup Utility Connecting to the MGMT 10/100/1000 Ethernet PortStep 5 Enter yes to enter setup mode Step 9 Enter a name for the switch This step denies traffic flow for all members of the default zone Verifying the Module Status 2-10