Once the router has been configured to meet FIPS 140-1 Level 2 requirements, the router cannot be accessed without signs of tampering. To seal the system, apply serialized tamper-evidence labels as follows:

Clean the cover of any grease, dirt, or oil before applying the tamper evidence labels. Alcohol-based cleaning pads are recommended for this purpose. The ambient air must be above 10C, otherwise the labels may not properly cure.

The tamper evidence label should be placed so that the one half of the label covers the enclosure and the other half covers the 7206 VXR NPE-400 Input/Output Controller.

The tamper evidence label should be placed over the Flash PC Card slots on the Input/Output Controller.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 1.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 2.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 3.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 4.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 5.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the port adapter slot 6.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the network processing engine.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the power supply plate.

The tamper evidence label should be placed so that one half of the label covers the enclosure and the other half covers the redundant power supply plate.

The labels completely cure within five minutes.

Cisco 7206 VXR Router with ISA Security Policy

9

Image 9
Contents Introduction References 7206 VXR NPE-400 RouterTerminology Document OrganizationPort adapters 7206 VXR NPE-400 Cryptographic ModuleInput/Output Controller Module InterfacesLED Integrated Service Adapter Enabled Router Physical Interface Fips 140-1 Logical Interface Roles and ServicesCryptographic Officer Services User ServicesPhysical Security 7206 VXR NPE-400 Router Shows the tamper evidence label placements System Initialization and Configuration Initial SetupSelf-Tests Cryptographic Key ManagementRemote Access Non FIPS-Approved AlgorithmsProtocols World Wide Web Obtaining DocumentationDocumentation CD-ROM Ordering DocumentationObtaining Technical Assistance Contacting TAC by Using the Cisco TAC WebsiteCisco.com Technical Assistance CenterContacting TAC by Telephone