Cisco Systems SN 5428-2 manual 3 FCIP

Page 3
Figure 1-3 FCIP

Chapter 1 Before Configuring SN 5428-2 Storage Router Software

SN 5428-2 Storage Router Overview

Fibre Channel over IP (FCIP) enables SN 5428-2 Storage Routers to provide connectivity by tunneling through an IP network between storage area networks (SANs). (See Figure 1-3.)

Figure 1-3 FCIP

 

 

FC hosts and

 

FC hosts and

storage devices

 

 

storage devices

SN 5428-2

SN 5428-2

 

SAN

IP

SAN

The SN 5428-2s connect SANs by tunneling though the IP network

91658

In addition to providing services for accessing storage over IP networks, the SN 5428-2 Storage Router software provides the following services:

VLAN Access Control—provides IP access control to storage based on a VLAN identifier (VID) number (in addition to access control through access lists)

Authentication—provides iSCSI, Enable and Login authentication using AAA authentication methods

High Availability (HA)—provides the ability to group storage routers in a cluster for intelligent failover and other cluster-related functions (for SCSI routing only)

E_Port with FC Fabric Zoning—provides the ability to connect FC ports to FC switches and participate in fabric zoning, manage zoning, and support zone mergers

SNMP/MIB support—provides network management of the SN 5428-2 through SNMP using selected MIBs

Gigabit Ethernet Interface features—provides the ability to assign a management IP address per Gigabit Ethernet interface, multiple IP addresses per SCSI routing instance, and an optional secondary Gigabit Ethernet interface per IP address used for SCSI routing or SN 5428-2 management. When the SN 5428-2 is deployed for FCIP, provides primary and optional secondary Gigabit Ethernet interfaces to the FCIP peer.

FCIP data compression—enables the SN 5428-2 to dynamically compress FCIP data traffic for better channel bandwidth utilization

Buffer credit extension—enables the SN 5428-2 to donate buffer credits from a donor port to selected FC ports

Secure Sockets Layer (SSL) support—provides HTTPS connection for secure access through the web-based GUI

Secure Shell (SSH) protocol version 2 support—provides high encryption and authentication for interactive management sessions, and is a common replacement for Telnet

Routing Information Protocol (RIP) listening support—allows the SN 5428-2 to learn dynamic routing using RIP (version 1 or version 2) listening

Service Location Protocol (SLP) support—provides the ability to advertise targets of specified SCSI routing instances to initiators or servers that use SLP

Internet Storage Name Service (iSNS) support—provides the ability to register iSCSI targets with an iSNS server, allowing iSCSI initiators to dynamically discover available storage targets

Cisco SN 5428-2 Storage Router Software Configuration Guide

 

OL-4691-01

1-3

 

 

 

Image 3
Contents SN 5428-2 Storage Router Overview, page SCSI Routing Overview, page Mixed Mode Overview, page VLAN Access Overview, pageAuthentication Overview, page Where to Go Next, pageSN 5428-2 Storage Router Overview Figure 1-3 FCIP Basic Network Structure, page SCSI Routing Mapping and Access Control, pageSCSI Routing Overview Routing SCSI Requests and Responses, pageRouting SCSI Requests and Responses SCSI Routing Mapping and Access Control Basic Network StructureFigure 1-7 SCSI Routing Basic Network Structure Table 1-2 Target-only Mapping Example DatabaseWebserver2000 Table 1-1 Target-and-LUN Mapping ExampleAccess for SCSI routing is controlled in the IP hosts and the storage router. In an IP host, the iSCSI driver is configured with the Gigabit Ethernet IP address of the SCSI routing instance in the storage router with which the host is to transport SCSI requests and responses. In a storage router, access is controlled through an access list and a VLAN identifier VID number of the hosts. Additionally, access can be further controlled in the SN 5428-2 through authentication. See the “Authentication Overview” section on page 1-24 for more information about authentication Available Instances of SCSI Routing Figure 1-8 SCSI Routing Storage Mapping and Access Control ConceptTable 1-3 SCSI Routing Storage Mapping and Access Control Concept 1-10 Transparent SCSI Routing Mapping and Access Control, pageTransparent SCSI Routing Overview Available Instances of Transparent SCSI Routing, pageFigure 1-11 Transparent SCSI Routing Actions 1-11Transparent SCSI Routing Mapping and Access Control 1-12Basic Network Structure Table 1-4 Transparent SCSI Routing Mapping Example 1-13Drive LUN 1-14Intelligent Storage Array and SCSI RoutingAvailable Instances of Transparent SCSI Routing Using FCIP to Route Fibre Channel PacketsUsing FCIP to Route Fibre Channel Packets, page FCIP OverviewFCIP Network Structures 1-16Figure 1-15 FCIP Actions 1-17 Figure 1-16 FCIP Redundant WAN ConfigurationFigure 1-17 FCIP Fully Redundant Configuration Mixed Mode Overview 1-18Figure 1-18 Multisite FCIP Configuration 1-19 Figure 1-19 Mixed Mode Overview SCSI routing and FCIPFigure 1-20 Mixed Mode Overview Transparent SCSI routing and FCIP 1-20 VLAN Access OverviewZoning Overview 1-21Figure 1-21 VLAN Access Overview Zoning comprises zones, zone sets, aliases, and zone databases 1-22Fibre Channel Interface Overview Gigabit Ethernet Interface Overview1-23 1-24 Authentication OverviewSN 5428-2 Cluster Management Overview Interface Naming1-25 Where to Go Next 1-26a a n 1-27 1-28
Related manuals
Manual 78 pages 51.81 Kb Manual 16 pages 56.35 Kb Manual 22 pages 17.61 Kb

SN 5428-2 specifications

Cisco Systems SN 5428-2 is a highly versatile and advanced network storage solution designed to meet the demands of data center environments. This robust storage appliance integrates cutting-edge technologies to provide high performance, reliability, and scalability, making it an ideal choice for organizations looking to enhance their data management capabilities.

One of the main features of the SN 5428-2 is its high-density architecture, which allows for efficient utilization of space while providing ample storage capacity. The system supports multiple drive configurations, including HDDs and SSDs, enabling users to tailor their storage solutions based on performance needs and budget constraints. With a significant amount of raw capacity available, organizations can effortlessly handle large volumes of data and support intensive workloads.

The SN 5428-2 boasts advanced data protection technologies, ensuring that critical information is safeguarded against loss or corruption. Features like RAID support provide redundancy and fault tolerance, while snapshot and cloning capabilities offer quick recovery options in case of data breaches or system failures. Additionally, built-in encryption features help protect sensitive data both at rest and in transit.

The appliance incorporates state-of-the-art networking capabilities as well. With support for various network protocols, including iSCSI and Fibre Channel, the SN 5428-2 can seamlessly integrate into existing infrastructures. This adaptability allows for easy connection with different servers and storage systems, facilitating a more cohesive and efficient operational environment.

Furthermore, the SN 5428-2 is designed with scalability in mind. Organizations can start with a basic configuration and expand as their storage needs grow by adding additional drives or connecting more appliances. This flexibility ensures that businesses can continue to meet their evolving data demands without the need for complete system overhauls.

Management and monitoring of the SN 5428-2 are simplified through a user-friendly interface that provides real-time insights into system performance, capacity utilization, and health status. Administrators can easily configure and manage storage resources, making operational tasks more efficient.

In summary, Cisco Systems SN 5428-2 stands out in the realm of storage solutions by combining high density, robust data protection, advanced networking capabilities, and remarkable scalability. Its thoughtful design and features make it an essential tool for organizations looking to enhance their data storage infrastructure and improve overall performance. With its reliable and efficient performance, the SN 5428-2 is well-suited for a wide array of data center applications.