The MPS14
The slimline MPS14 power supply uses switch mode technology to generate the DC voltages required by the console. It will operate from a wide range of ac mains input voltages. Full protection and thermally controlled fan cooling ensures the power unit will operate consistently. The MPS14 also has a built in combiner for connection to a second supply for backup.
ON PROTECT
ADVANCED TECHNOLOGY / HIGH POWER DELIVERY / AUTO COMBINING
MPS14 CONSOLE POWER SUPPLY
PIN 1 = + 12V @ 4A
PIN 2 = + 17V @ 6.5A
PIN 3 = A GND
PIN 4 = A GND
PIN 5 = D GND
PIN 6 = + 48V @ 500mA
PIN 7 = -17V @ 6.5A
+ 17V | + 12V | + 48V | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION | DO NOT OBSTRUCT VENTILATION OPENINGS. |
DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE. | |
| THIS APPARATUS MUST BE EARTHED BY THE POWER CORD. |
| WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK |
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. | DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. |
CAUTION: FOR CONTINUED PROTECTION AGAINST RISKOF FIRE REPLACE FUSE
WITH SAME TYPE AND RATING. DISCONNECT SUPPLY BEFORE CHANGING FUSE.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
COUPER L'ALIMENTATION AVANT DE CHANGER LE FUSIBLE.
MAINSINPUT
FUSE
T
T5A 250V
100V - 230V.AC
S/No MADE INENGLAND
Installation
Free standing
The MPS14 can be operated as a freestanding unit without requiring any special cooling arrangement, but should not be accidentally or deliberately covered in any way. Always stand the unit on a firm flat surface well away from any soft furnishings or carpet.
Rack mounting
The MPS14 is designed as a 19 inch rack mount unit and will occupy 2U (3.5 inches) of rack space. A pair of M4 threaded holes on each side at the rear of the chassis are provided for fixing brackets for supporting the rear of the unit.
An important consideration when
Good ventilation below the unit, in the floor or back of the rack, will ensure a path for continuous airflow.
Other equipment in the rack which is known not to produce a significant amount of heat should be mounted below the unit. Equipment which also relies on good airflow within the rack (i.e. most power amplifiers and other power supplies) should be given due consideration and some space should be provided between such units and between the MPS14 unit. Forced convection, by means of a
Location
As with any power supply that contains switch mode technology, it is preferable to provide a degree of physical isolation of the unit from other equipment, particularly that which carries low level audio signals, to avoid any possible interference
6 | MPS14 User Guide |