Brocade Communications Systems 6710-54 Assigning permanent passwords, Serial cable pinouts

Page 7

1.Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation or terminal device.

If the serial port on the workstation or terminal device is RJ45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ45 connector into the RJ45 serial port on the workstation.

2.Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a UNIX environment), and configure the application as follows:

In a Windows environment, enter the following values: 9600 bits per second, 8 databits, no parity, 1 stop bit, and no flow control.

In a UNIX environment using TIP, enter the following string at the prompt:

tip /dev/ttyb -9600

If ttyb is already in use, use ttya instead.

Serial cable pinouts

The serial port is located on the port side of the VDX 6710. The switch uses an RJ-45 connector for the serial port. An RJ-45 to DB9 adaptor is also provided with the VDX 6710. The cable supplied with the switch is a rollover cable.

NOTE

To protect the serial port from damage, keep the cover on the port when not in use.

The serial port can be used to connect to a workstation to configure the VDX 6710 IP address before connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set to None.

Table 2 lists the serial cable pinouts.

TABLE 2

Serial cable pinouts

 

 

 

 

PIN

Signal

Description

 

 

 

1

Not supported

NA

 

 

 

2

Not supported

NA

 

 

 

3

TXD

Transmit data

 

 

 

4

GND

Logic ground

 

 

 

5

Not supported

NA

 

 

 

6

RXD

Receive data

 

 

 

7

Not supported

NA

 

 

 

8

Not supported

NA

 

 

 

Assigning permanent passwords

When you log in for the first time, Brocade recommends that you change the passwords for the default accounts.

The factory-configured default accounts on the switch are admin, user, and root. Use the default administrative account as shown in Table 3 to log in to the switch for the first time and to perform the basic configuration tasks.

Brocade VDX 6710-54 QuickStart Guide

7 of 12

Publication Number: 53-1002338-02

 

Image 7
Contents Brocade VDX Brocade Communications Systems, Incorporated Electrical considerations Installation and safety considerationsOverview Items included with the Brocade VDXRack considerations Environmental considerationsRecommendations for cable management Items required for installation Standalone installation for a Brocade VDXCreating a serial connection Rack installation for a Brocade VDXProviding power to the switch Verifying operationSerial cable pinouts Assigning permanent passwordsChanging the default account passwords Setting the switch IP addressUsing Dhcp to set the IP address Enabling VCS mode Enabling and disabling Brocade VCS modeDisabling VCS mode Connecting network devices Configuring switch portsInstalling and connecting an SFP or SFP+ transceiver Brocade VDX 6710-54 QuickStart Guide Publication Number Connecting to workstations, servers, or routers Connecting to Ethernet or Fast Ethernet hubsConnecting a network device to a fiber port

6710-54 specifications

Brocade Communications Systems has made a significant impact on the networking industry, and one of its prominent products is the Brocade 6710-54 switch. This advanced Ethernet switch is designed to meet the demands of modern data centers and enterprise networks, delivering high performance, reliability, and scalability.

The Brocade 6710-54 features 54 Ethernet ports, which typically include a combination of 10 Gigabit SFP+ and Gigabit Ethernet ports. This flexibility allows organizations to deploy a variety of network devices, catering to different bandwidth needs without significant overhead. The switch is well-suited for both Layer 2 and Layer 3 networking, providing a versatile solution for complex connectivity requirements.

One of the standout characteristics of the Brocade 6710-54 is its exceptional scalability. Organizations can easily expand their networks to accommodate additional devices or increased traffic without sacrificing performance. The switch supports advanced stacking capabilities, allowing multiple units to work in tandem as a single logical unit. This simplifies management and enhances network reliability by providing redundancy.

In terms of technology, the Brocade 6710-54 supports industry-leading features such as SDN (Software-Defined Networking) and network automation. This allows for greater agility in managing network resources and simplifies the integration of new features as business needs evolve. The switch also includes features like Virtual LANs (VLANs) for efficient traffic segmentation, and Quality of Service (QoS) to prioritize critical applications, ensuring optimal performance in diverse environments.

The Brocade 6710-54 also emphasizes security, with robust options for access control, authentication, and encryption. Features such as IEEE 802.1X port-based authentication and access control lists (ACLs) enhance the security posture of the network, protecting sensitive data from unauthorized access.

Brocade’s commitment to energy efficiency is evident in the design of the 6710-54. The switch incorporates power-saving features that reduce energy consumption without compromising performance, thereby contributing to overall cost savings for organizations.

With a reliable architecture, advanced features, and support for emerging networking technologies, the Brocade 6710-54 is a compelling choice for businesses looking to enhance their network infrastructure. Its ability to handle the increasing demands of data traffic makes it suitable for a wide range of applications, ultimately helping organizations to achieve their operational goals efficiently and effectively.