Brocade Communications Systems 6710-54 Assigning permanent passwords, Serial cable pinouts

Page 7

1.Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation or terminal device.

If the serial port on the workstation or terminal device is RJ45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ45 connector into the RJ45 serial port on the workstation.

2.Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a UNIX environment), and configure the application as follows:

In a Windows environment, enter the following values: 9600 bits per second, 8 databits, no parity, 1 stop bit, and no flow control.

In a UNIX environment using TIP, enter the following string at the prompt:

tip /dev/ttyb -9600

If ttyb is already in use, use ttya instead.

Serial cable pinouts

The serial port is located on the port side of the VDX 6710. The switch uses an RJ-45 connector for the serial port. An RJ-45 to DB9 adaptor is also provided with the VDX 6710. The cable supplied with the switch is a rollover cable.

NOTE

To protect the serial port from damage, keep the cover on the port when not in use.

The serial port can be used to connect to a workstation to configure the VDX 6710 IP address before connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set to None.

Table 2 lists the serial cable pinouts.

TABLE 2

Serial cable pinouts

 

 

 

 

PIN

Signal

Description

 

 

 

1

Not supported

NA

 

 

 

2

Not supported

NA

 

 

 

3

TXD

Transmit data

 

 

 

4

GND

Logic ground

 

 

 

5

Not supported

NA

 

 

 

6

RXD

Receive data

 

 

 

7

Not supported

NA

 

 

 

8

Not supported

NA

 

 

 

Assigning permanent passwords

When you log in for the first time, Brocade recommends that you change the passwords for the default accounts.

The factory-configured default accounts on the switch are admin, user, and root. Use the default administrative account as shown in Table 3 to log in to the switch for the first time and to perform the basic configuration tasks.

Brocade VDX 6710-54 QuickStart Guide

7 of 12

Publication Number: 53-1002338-02

 

Image 7
Contents Brocade VDX Brocade Communications Systems, Incorporated Electrical considerations Installation and safety considerationsOverview Items included with the Brocade VDX Rack considerations Environmental considerations Recommendations for cable management Items required for installation Standalone installation for a Brocade VDXCreating a serial connection Rack installation for a Brocade VDXProviding power to the switch Verifying operationSerial cable pinouts Assigning permanent passwordsChanging the default account passwords Setting the switch IP addressUsing Dhcp to set the IP address Enabling VCS mode Enabling and disabling Brocade VCS modeDisabling VCS mode Connecting network devices Configuring switch portsInstalling and connecting an SFP or SFP+ transceiver Brocade VDX 6710-54 QuickStart Guide Publication Number Connecting to workstations, servers, or routers Connecting to Ethernet or Fast Ethernet hubsConnecting a network device to a fiber port