Included Accessories | Model DESCRIPTION | | | page | PART # | |
EPS 1210 B | | Extron Desktop Power Supply - 12VDC, 2A.. . | . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . | page 694 | 70-055-01 | |
NETXC M-M | | Male to Male RJ-45 Network Crossover Cable, 6' (1.8 m) | . . . . . . . . . . . | page 418 | 26-591-01 | |
Backlit Button Labels | | Text Button Labels | . . . . . . . . . . . | n/a | 33-954-01 | |
Backlit Button Labels | | Icon Button Labels | . . . . . . . . . . . | n/a | 33-955-01 | |
MR 200 | | Two-Gang Mud Ring - Black | . . . . . . . . . . . | page 821 | 70-519-22 | |
MR 200 | | Two-Gang Mud Ring - White | . . . . . . . . . . . | page 821 | 70-519-23 | |
Optional Accessories | Model DESCRIPTION | | | page | PART # | |
CM-9BLB | | Nine-Button Control Module - Quad Space AAP | . . . . . . . . . . . | page 394 | 70-494-02 | |
CFG Cable | | 9-pin D Female to 2.5 mm TRS Configuration Cable | . . . . . . . . . . . | page 418 | 70-335-01 | |
IPA T RLY4 | | IP Link® Accessory with Four Relays | . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . | page 486 | 60-545-03 | |
IRCM-DV+ | | Dual-Function DVD and VCR IR Control Module | . . . . . . . . . . . | page 393 | 70-220-02 | |
IR Emitter and Shield Kit | | IR Emitter Kits | . . . . . . . . . . . | page 416 | 70-283-01 | |
MLC IR/RS-232-6' | | One Projector Communication Cable - Plenum | . . . . . . . . . . . | page 419 | 26-621-06 | |
MLC PW/RS-232/VC-6' | | One Power, Switcher Communications and MPA Volume Control Cable - | | | |
| | | Plenum | . . . . . . . . . . . | page 419 | 26-626-06 | |
MLS 100 A | | Four Input Stereo Audio MediaLink™ Switcher | . . . . . . . . . . . | page 428 | 60-497-01 | |
MLS 102 VGA | | Two Input VGA-QXGA and Four Input Stereo Audio MediaLink™ Switcher | page 429 | 60-497-04 | |
MLS 304MA | | Four Input MediaLink™ Switcher with Mono Audio Amplifier | . . . . . . . . . . . | page 435 | 60-550-01 | |
MPA 122 | | 22 Watt Two Channel Integrated MPA - Mini Power Amplifier | . . . . . . . . . . . | page 658 | 60-668-01 | |
SCP 104 | | Secondary Control Panel for MLC 104 IP Plus and System 5 IP | . . . . . . . . . . . | page 397 | 60-672-02 | |
UC50' (50' / 15 m) | | Universal Projector Control Cable: 9-pin D Female to Bare Wires - 50' (15.2 m). . . | page 419 | 26-518-01 | |
UCM RAAP | | Universal Controller Mounting Rack Kit - Black | . . . . . . . . . . . | page 410 | 70-344-02 | |
| SPECIFICATIONS | | | General | | | | |
| Control — host ports | | | External power supply | 100 VAC to 240 VAC, 50/60 Hz, external, to 12 VDC, 1 A, regulated | |
| | | Power input requirements | | | | |
| Serial host port | 1 bidirectional RS-232 front panel 2.5 mm mini stereo jack | 12 VDC, 0.305 A (includes MLC 104 IP Plus and IRCM-DV+) | |
| MLC 104 IP Plus DV+ | |
| Baud rate and protocol | 38400, 8 data bits, 1 stop bit, no parity | |
| All other models | 12 VDC, 0.285 A (0.305 A if used with an optional IRCM-DV+) | |
| Serial control pin | | | | |
| | | | NOTE: An MLC 104 IP Plus Series controller must be powered by its own power supply. It cannot be powered by an | |
| configurations | Mini stereo jack: tip = TX, ring = RX, sleeve = GND | |
| MLS switcher. | | | | |
| Ethernet host port | 1 RJ-45 female | | | | | | |
| | | Temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing | |
| Ethernet data rate | 10/100Base-T, half/full duplex with autodetect | |
| Ethernet protocol | ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP | Rack mount | Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing | |
| Ethernet default settings | Link speed and duplex level = autodetected | No, but wall and furniture mountable | | |
| | IP address = 192.168.254.254 | MLC 104 IP Plus DV+ | | |
| | Subnet mask = 255.255.0.0 | | | All other models | Yes, with optional rack mounting kits, and also wall- and furniture-mountable | |
| | Default gateway = 0.0.0.0 | | | Enclosure type | with optional mounting kits | | |
| | DHCP = off | | | High-impact plastic | | |
| Web server | Up to 200 simultaneous sessions | MLC 104 IP DV+ | | |
| | 7.25 MB nonvolatile user memory | All other models | Metal | | | |
| Secondary control panel (SCP) | (1) 3.5 mm 5-pole direct insertion captive screw connector | Enclosure dimensions | 4.5” H x 4.6” W x 0.1” D (11.4 cm H x 11.7 cm W x 0.3 cm D) (2 gang) | |
| Program control | Extron’s Global Configurator for Windows® | MLC 104 IP Plus faceplate. . | |
| | Extron’s Simple Instruction Set (SIS™) | MLC 104 IP Plus AAP and MLC 104 IP Plus DV+ | | |
| | Microsoft® Internet Explorer, Telnet | faceplates | 4.5” H x 8.2” W x 0.1” D (11.4 cm H x 20.9 cm W x 0.3 cm D) (4 gang) | |
| IR learning frequencies | 30 kHz to 62 kHz | | | MLC 104 IP Plus L faceplate 3.15” H x 6.5” W x 0.1” D (8.0 cm H x 16.5 cm W x 0.3 cm D) | |
| IR learning distance | 2” (5.1 cm) to 12” (30.5 cm) from the front panel | MLC 104 IP Plus DV+ | 2.7” H x 3.4” W x 1.8” D (6.9 cm H x 8.6 cm W x 4.6 cm D) and 2.7” H x 2.6” W | |
| Control — serial ports | | | device | |
| | | | x 0.9” D (6.9 cm H x 6.6 cm W x 2.3 cm D) | |
| Display control port | (1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional | | |
| | (Depth excludes knobs and buttons. Fits some 4 gang wall boxes. Allow at least | |
| Switcher control port | RS-232 control (±5 V) | | | | 1.9” [4.8 cm] depth in the wall or furniture.) | |
| (1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional | All other models device | 2.7” H x 3.4” W x 1.8” D (6.9 cm H x 8.6 cm W x 4.6 cm D) | |
| Baud rate and protocol | RS-232 control (±5 V) | | | | (Depth excludes knob and buttons. Fits some 2 gang boxes. | |
| | | | | Allow at least 1.9” [4.8 cm] depth in the wall or furniture.) | |
| (RS 232) | 115200 to 300 baud (9600 baud = default); 8 (default) or 7 data bits; | Product weight | | | | |
| | 1 (default) or 2 stop bits; no parity (default), or even or odd parity | MLC 104 IP Plus DV+ | 2.1 lbs (1.0 kg) | | |
| Control — IR port | | | All other models | 1.9 lbs (0.9 kg) | | |
| IR control port | (1) 3.5 mm direct insertion captive screw connector, 2 pole | .. . . . . . . . . . . . . . . . .Shipping weight | 6 lbs (3 kg) | | | |
| Vibration | ISTA 1A in carton (International Safe Transit Association) | |
| | TTL level (0 to 5 V) infrared control up to 1 MHz | |
| | Listings | UL, CUL | | | |
| Digital I/O control | | | | | |
| | | Compliances | CE, FCC Class A, VCCI, AS/NZS, ICES | | |
| Number/type | 3 digital input/output (configurable) | . .MTBF | 30,000 hours | | | |
| Connector | (1) 3.5 mm direct insertion captive screw connector, 4 pole | Warranty | 3 years parts and labor | | |
| Pin configuration | 1, 2, 3 = digital inputs/outputs 1, 2, and 3; GND = GND | NOTE: All nominal levels are at ±10%. Specifications are subject to change without notice. | |
| Digital inputs | | | | | | | | |
| Input voltage range | 0-12 VDC | | | | | | | |
| Input impedance | 28k ohms | | | | | | | |
| Programmable pullup | 2k ohms to +5 VDC | | | | | | | |
| Threshold low to high | >2.8 VDC | | | | | | | |
| Threshold high to low | <2.0 VDC | | | | | | | |
| Digital outputs | 250 mA sink from 24 VDC, maximum | | | | | |