Extron electronic MLS 506SA, MLS 506MA, MLS 306 manual Effects submenu

Page 25

The following flowchart shows the main menus and submenus available for all four switcher models. Items within the dashed lines are not offered on all models.

Power

on

FIRMWARE

Ver 1.XX

EXTRON

2 sec.

INPUT

 

MLS506SA

2 sec.

#2

 

 

Video input format

selection/configuration is not available

or necessary for the MLS 306.

RGB delay time:

MENU

NEXT

VIDEO

CONFIG

MENU

Select the video type

Select

for inputs 1–3.

Default: Vid.

another

 

input.

Input #2

<Vid>YUV

3

VOLUME

ADJUST

Input #2

Vid<YUV>

Input #3

<Vid>YUV

VOLUME

ADJUST

Input #3

Vid<YUV>

Select

another

input.

5

Inputs 4–6

are RGB only.

Input #5

RGB Only

NEXT

0 seconds to 5 seconds in 0.5 sec. intervals.

RGBdelay

0.0 sec

VOLUME

ADJUST

RGBdelay

5.0 sec

NEXT / MENU

Set audio output level

Adjust bass

Adjust treble

per input.

per input (2dB

per input (2dB

MLS 306/506: -15dB to +09dB

increments).

increments).

MLS 506MA/506SA: 0 to 100 steps

-14dB to +14dB

-14dB to +14dB

AUDIO

ADJUST

MENU

NEXT

Level

#2 050

VOLUME

ADJUST

Level

#2 067

NEXT

NEXT

 

Bass

#2

+00dB

VOLUME

ADJUST

Bass

#2 -08dB

Treble

#2 +00dB

VOLUME

ADJUST

Treble

#2 +06dB

MENU

Set the overall left / right audio output balance.

 

The Effects submenu

 

is available for the

 

MLS 506MA and

 

MLS 506SA only.

 

Default: the Effects

Stereo: Audio Out

Return is disabled.

Enable: the Effects

outputs stereo audio.

Return will be active,

Mono: the Audio Out

its input will be sent

signal is the same

to the Audio Out and

on both left & right.

amplified outputs.

The Speaker Load submenu is available for the MLS 506SA only.

4ohm: 4 ohm load on stereo amplified output.

8ohm: 8 ohm load on stereo amplified output.

NEXT

NEXT

Output

NEXT

AUDIO

Balance

Effects

SETTINGS

––––––––

M<Stero>

E<Dsabl>

MENU

VOLUME

VOLUME

VOLUME

ADJUST

ADJUST

ADJUST

Balance

 

Output

 

Effects

––––––––

 

<Mono>St

 

<Enabl>D

 

 

 

 

 

MENU

 

EXIT

 

NEXT

 

MENU

 

 

 

or timeout

NEXT

SpkrLoad <4ohm> 8

VOLUME

ADJUST

SpkrLoad 4 <8ohm>

NEXT / MENU

MediaLink Switchers • Operation

3-5

Image 25
Contents MLS 306, MLS 506, MLS 506MA, MLS 506SA MediaLink SwitchersSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschTable of Contents Table of Contents, cont’d One Features and Options About the MediaLink SwitchersStandard features IntroductionTwo UL/Safety Requirements InstallationMounting the Switcher MLS 306 Rear Panel and CablingInput connections Power connectionVideo output connections Control connections Audio output connectionsPin RS-232 function Description Contact closure MLS 506 Rear Panel MLS 506, MLS 506MA, and MLS 506SA Rear Panels and CablingVideo input connections for MLC 506/506MA/506SA inputs RGB output connections for MLC 506/506MA/506SA Connecting a 4 ohm load to the mono amplified ouputOhm or Connecting an 8 ohm load to the mono amplified outputAudio processing connections MLS 506MA, MLS 506SA only MediaLink Switcher to an MLC Setting the -6dB Jumpers JMP1 and JMP2 -6dB Audio Jumpers MLS 506MA Rear Panel Top View MLS 506MA Front PanelExtron MLS Application DiagramsThree MediaLink Switchers Operation Front Panel Features and Basic OperationOperation Extron MLS Moving through menus by using front panel controls Menus, Configuration, and AdjustmentsMenu overview Effects submenu Menu details System resetExecutive mode Remote Control of the MLSOperation, cont’d Four RS-232 Programmer’s Guide Serial CommunicationHost-to-MLS communications Symbol definitions Using the command/response tablesCommand Ascii Command Response Additional description Ascii to Hex conversion tableSerial Communication, cont’d Audio treble adjustment per inputAudio mute overall Audio bass adjustment per inputCommand Ascii Command Response Values Command/response table for special function SIS commandsUsing the control program Installing the softwareControl Software for Windows Special features User ModeSwitcher MLS Config Saving and restoring configurationsKey to file names Using the help programFile name Description AAppendix a Specifications Specifications, Part Numbers, and AccessoriesAudio Specifications, Part Numbers, and Accessories, cont’d Accessories Part Numbers and AccessoriesMiscellaneous accessories Part number Included partsSpecifications, Part Numbers, and Accessories, cont’d AppendixBB Using the software to make labels Labeling Buttons on the SwitcherMediaLink Switchers Labeling LabelingLabel Templates Labeling, cont’d FCC Class a Notice Extron’s Warranty Extron Electronics, USA
Related manuals
Manual 4 pages 28.11 Kb

MLS 306, MLS 506MA, MLS 506, MLS 506SA specifications

Extron Electronics, a leading provider of AV control and signal distribution solutions, offers a range of versatile and user-friendly products. Among these, the MLS 306, MLS 506SA, MLS 506MA, and MLS 506 stand out as robust multimedia learning solutions designed to meet the diverse needs of educational environments.

The MLS 306 is particularly designed for smaller classrooms, providing essential AV capabilities in a compact format. It features user-friendly control capabilities that allow teachers to easily manage presentations and multimedia content with minimal technical know-how. The MLS 306 includes multiple input options, supporting various devices such as computers, document cameras, and DVD players. This model emphasizes efficiency and practicality, making it an ideal choice for contemporary educational settings.

For larger classrooms or comprehensive AV setups, the MLS 506 series comes into play. The MLS 506SA (Simple AV) model is tailored for straightforward AV applications, featuring intuitive control interfaces that allow users to easily switch between sources and manage audio and video output. This model ensures seamless integration with other AV equipment, providing a user-friendly experience ideal for instructors focused on effective teaching.

In contrast, the MLS 506MA (Media AV) version expands capabilities for more complex multimedia environments, supporting additional inputs and outputs for advanced AV systems. Its advanced functionality includes the ability to control lighting and other environmental factors, enhancing the learning experience by creating an optimal classroom setting. With customizable presets, educators can quickly adapt the environment for various activities.

The standard MLS 506 model serves as a comprehensive solution, offering a blend of advanced control and connectivity features. This model stands out for its integration of Extron’s industry-leading technologies, including GlobalViewer Enterprise software, allowing for remote monitoring and management of AV systems over the network. This capability is particularly beneficial for IT administrators managing multiple classroom environments.

All models in the MLS series feature robust reliability and are built with Extron’s commitment to high-quality design. Moreover, they include user-friendly interfaces, ensuring that both educators and students can focus on learning without being hindered by complicated technology. Collectively, the Extron MLS 306, MLS 506SA, MLS 506MA, and MLS 506 represent a significant advancement in educational technology, bridging the gap between teaching and technology for enhanced learning experiences.