Remote Control, cont’d
Connecting an MMX 32 AAP or MMX 32 MAAP control panel
Each Extron MMX 32 AAP and MMX 32 MAAP contact closure remote control panel can control one output on the switcher. To connect a panel to the switcher, wire the captive screw connectors on the rear of the panel as follows.
43
2 5
1
Figure 3-8 — MMX 32 AAP rear panel
34
2 | 5 |
1
Figure 3-9 — MMX 32 MAAP rear panel
Input Selection connector
1Input 1 pole — Connect this pole of the captive screw connector to pin 1 (if the panel will control output 1) or pin 7 (if the panel will control output 2) of the MMX 32 VGA A’s Remote connector.
2Input 2 pole — Connect this pole of the captive screw connector to pin 4 (output 1) or pin 8 (output 2) of the MMX 32 VGA A’s Remote connector.
3Input 3 pole — Connect this pole of the captive screw connector to pin 6 (output 1) or pin 9 (output 2) of the MMX 32 VGA A’s Remote connector.
Tally Power connector
45 VDC pole — Connect this pole of the captive screw connector to the 5 VDC pole of the Tally Pwr connector on the
MMX 32 VGA A.
5GND pole — Connect this pole of the captive screw connector to the ground pole of the Tally Pwr connector on the
MMX 32 VGA A.
Control
Document
Camera | Extron | |
MMX 32 VGA A | ||
| ||
| Matrix Switcher |
Audio System
| Podium | LCD Monitor |
| |
Extron | Computer |
| ||
with Audio | Projector | |||
| ||||
AAP 102 with |
|
| ||
|
|
| ||
MMX AAP |
| Laptop |
|
Figure 3-10 — Typical MMX 32 VGA A application using contact closure remote control
Only one MMX 32 AAP or MMX 32 MAAP control panel can be used to control each output.
Extron recommends shielded twisted pair cable, such as STP 22 dual plenum cable, part
MMX 32 VGA A • Remote Control |