Extron electronic IPA T RLY4 manual Specifications, Relay control, General

Page 6

Specifications

Relay control

Relay control ports number/type ..

4 momentary

Relay control connectors

(1) 3.5 mm captive screw connectors, 5 pole,

 

for control input and power

 

(4) 3.5 mm captive screw connectors, 3 pole,

 

NO & NC for configurable relay outputs

Relay coil operating current

0.015 A (nominal), 0.025 A (maximum). The coil

 

limits the current; no external resistance is required.

Relay control contact rating

24 V, 1 A

General

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

Rack mount

No

Enclosure type

Plastic

Enclosure dimensions

1.0" H x 2.4" W x 2.3" D

 

2.5 cm H x 6.1 cm W x 5.8 cm D

Product weight

0.1 lb (<0.1 kg)

Shipping weight

1 lb (1 kg)

Vibration

ISTA 1A in carton

 

(International Safe Transit Association)

Listings

UL, CUL

Compliances

CE, FCC Class A, VCCI, AS/NZS, ICES

MTBF

30,000 hours

Warranty

3 years parts and labor

NAll nominal levels are at ±10%.

NSpecifications are subject to change without notice.

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Front Panel Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Front Panel Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

NThis unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance with FCC emissions limits.

Extron USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794 +1.919.863.1797 FAX

Extron Europe

Extron Asia

Extron Japan

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

+31.33.453.4040

+65.6383.4400

 

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

 

 

 

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568 +86.21.3760.1566 FAX

Extron Middle East

+971.4.2991800 +971.4.2991880 FAX

© 2009 Extron Electronics. All rights reserved.

Image 6
Contents Relay Accessory Box IPA T RLY4Introduction DescriptionConnections Input connectionsConnections Output connectionsWiring diagram for connection to a screen controller OperationSpecifications Relay controlGeneral
Related manuals
Manual 1 pages 55.25 Kb

IPA T RLY4 specifications

The Extron Electronics IPA T RLY4 is a state-of-the-art audio relay switcher designed for sophisticated AV system control. It serves as an essential component for simplifying the integration of audio and control signals in various professional environments such as corporate, educational, and entertainment settings. Equipped with four relay outputs, the IPA T RLY4 allows for easy control over audio routing to different devices, enabling users to create dynamic and responsive audio experiences.

One of the standout features of the IPA T RLY4 is its ability to facilitate seamless audio switching. It incorporates relay technology that ensures minimal audio signal degradation, allowing users to maintain audio quality even when switching between multiple sources. This is particularly beneficial in critical applications where sound fidelity is paramount.

The IPA T RLY4 also includes advanced control options, encompassing both manual and automated functionalities. Users can integrate the device with other Extron control systems or third-party controllers for comprehensive AV management. This flexibility empowers users to create customized control schemes that enhance operational efficiency and user experience. Additionally, the IPA T RLY4 supports Extron’s global configuration and programming software, which aids in rapid installation and setup.

In terms of connectivity, the IPA T RLY4 is equipped with multiple input/output options, including balanced and unbalanced audio inputs. This diverse set of connectivity options makes it compatible with a wide range of audio sources, such as mixers, microphones, and amplifiers. Furthermore, the compact form factor of the device allows for easy installation in various environments, including equipment racks or standalone setups.

The IPA T RLY4 also features comprehensive signal indication capabilities, with LED indicators that provide real-time feedback on relay status and operational health. This diagnostic feature enhances troubleshooting efficiency, allowing users to quickly identify and rectify any issues that may arise.

Overall, the Extron IPA T RLY4 is an integral component for any audio system, combining robust audio switching, advanced control features, and superior signal integrity. Its design and functionalities cater to the needs of professionals seeking a reliable and efficient solution for managing audio distribution. With the IPA T RLY4, Extron continues to set benchmarks in the field of AV technology, ensuring that users receive the best performance and quality in their audio applications.