PPC 25 Installation Instructions, cont’d
Installation Procedure
Follow all local fire and safety code requirements for installation and anchoring. Install the PPC 25 Sensor in a
1. Open the top of the Priority Page Sensor.
From | Priority | |
PA system | ||
Page | ||
| ||
| Sensor |
Ceiling Mounted
Paging Speaker
To Priority
Page Controller
2. Loop either one of the speaker wire leads around the top (open) part of the Sensor, and connect it to the speaker as shown above. Connect the other speaker wire directly to the speaker. Polarity need not be observed.
•For a 25V or 70V system — wrap 5 to 8 loops.
•For a 4/8 ohm system — wrap 2 to 4 loops.
3. Close and latch the top of the Priority Page Sensor.
4. Cut an 18" section from the unterminated end of the supplied blue sensor cable for use in step 8 below.
5. Strip 3/16” of insulation from each conductor on the bare wire end of the blue sensor cable. Do not tin the leads.
6. Connect the stripped leads to the
Blue
Sensor
Cable
7. Route the connector end to the PPC 25 Controller, and plug it into the PAGING SENSOR receptacle.
8. Connect the 18”
When integrating the PPC 25 into a PoleVault System:
1. Connect the 18” cable (from step 4 above) from the RELAY OUT port on the PPC 25 Controller to the MUTE and GROUND pins on the PoleVault PVS 204SA VOL/MUTE port. Polarity need not be observed.
2. Use the included cable assembly (PN
|
| AMPLIFIED OUTPUTS |
| |
Extron |
|
| 4/8 |
|
|
| Ohms |
| |
PVS 204SA |
|
| ||
|
| L | R | Mute (center) |
Rear Panel | Tx Rx IR | 12V | DC VOL | |
|
|
| Ground (right) | |
| A B C |
| VOL/MUTE | |
|
| 10V |
|
Extron
PPC 25
Priority Page
Controller
Testing and Adjustment Procedure | Extron |
| |
To test that the classroom audio is muted when a | US | ||
PVS 204SA |
| ||
PA system announcment (page) occurs: | Twisted Pair |
| |
1. | Turn the classroom audio on. | Switcher |
|
| POW | ||
|
|
| ER |
2. | Speak into the PA system microphone. The classroom |
| |
| audio should be muted while the PA system page occurs, and be restored when the page ends. |
To Power Supply
3. If the PPC 25 fails to mute the classroom audio during a page, turn the SENSITIVITY adjustment clockwise.
4. If classroom audio is muted without a page occurring, turn the SENSITIVITY adjustment counterclockwise.
www.extron.com
Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd.
PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Japan
+81.3.3511.7655 FAX +81.3.3511.