Extron electronic MLA-VC10 user manual Setting the Configuration DIP Switches

Page 9

Installation and Setup, cont’d

Measuring voltage for a

Biamp Precedence CMA 60 amplifier

Several Biamp amplifiers have three screw terminals labeled “remote level”. The control voltage may be indicated (by a “C” in the following picture) on the

panel over the corresponding screw terminal, and the ground terminal is indicated with a .

Even if the voltage is indicated,

use a voltmeter (set to VDC) to measure the voltage as shown in the picture below. Write down the measured voltage for your reference when you set the DIP switches.

Measuring voltage for a Biamp Precedence CMA 60

For three-terminal amps, always connect the MLA- VC10 to the control voltage terminal and ground terminal of the amp’s control port. Leave the other terminal (+10V in this example) open (not connected).

The MLA-VC10 provides a control voltage (supply voltage) of between 0VDC and 10VDC. The MLA-VC10 can control amplifiers that use a higher control voltage. However, if the MLA-VC10 is used with devices that use a control port voltage above 10VDC, the maximum volume will not be reached.

Setting the Configuration DIP Switches

Set the Configuration DIP switches to the setting corresponding to the control voltage required by the amplifier or mixer.

See “Determining the Control Voltage” in this chapter. The table on the following two pages lists all the voltage levels that can be selected. Be sure to set each

switch all the way up or all the way

ON

 

CONFIGURATION

1

2

3

4 5 6 7 8

down, and do not leave it partway

 

 

 

 

 

between the two positions.

 

 

 

 

 

 

CONFIGURATION

UP

CONFIGURATION

 

 

 

 

 

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

 

 

 

 

 

ON

 

 

DOWN

 

 

 

 

 

 

 

0 to 10.0VDC

 

0 to 4.98VDC

 

 

 

 

NOT HALFWAY

2-6

MLA-VC10 • Installation and Setup

MLA-VC10 • Installation and Setup

2-7

Image 9
Contents User’s Manual MediaLink AccessoryPrecautions Extron’s WarrantyFCC Class a Notice Quick Start Guide MLA-VC10 Setting Up the MLA-VC10Table of Contents MLA-VC10 Table of Contents, cont’dAbout the MLA-VC10 IntroductionInstallation Front and Rear Panel FeaturesDetermining the Control Voltage Installation and Setup, cont’d Measuring voltage for a TOA A-903MK2 amplifierMeasuring voltage for a Peavey UMA 35T II amplifier Measuring voltage for a Biamp Precedence CMA 60 amplifier Setting the Configuration DIP SwitchesCabling Power MLA-VC10 Wiring the MLC/Power connectorRS-232 control Installation and Setup, cont’d OperationCommand/response table for SIS commands Installation and Setup, cont’d TroubleshootingAAppendix a Specifications Specifications, Part Numbers, and AccessoriesMLA-VC10 Functional Block Diagram Included PartsSpecifications, Part Numbers, Accessories, cont’d Specifications, Part Numbers, Accessories, cont’d