Default factory DIP Switch setting:
SW1 – RAID Setting DIP Switch
BZS – EZ –
M2 –
M1 –
M0 –
1.
2.
3.
Error buzzer function
Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start.
RAID mode 2 |
|
|
| OFF |
| OFF |
| OFF |
| OFF |
| OFF | |
RAID mode 1 | SW1 |
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
| |
RAID mode 0 |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BZS EZ M2 M1 M0
Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.
LED Pin Header
J3J1
P5 P0 P1 P2 P3 P4
Error LED
P5 P0 P1 P2 P3 P4
Activity LED
J1 – Drive Activity LED
P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card.
P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.
J3 – Error LED
P5 – error LED for eSATA host port
P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
www.addonics.com
Technical Support | Phone: | Email: www.addonics.com/support/query/ |