Addonics Technologies RR2035ASDML manual Technical Support M-F 830am 600pm PST Phone

Page 11

Notes about Spare Drives

If EZ mode is disabled (SW1:2 ON), all individual drives not configured as array members will be offered to the host adapter as separate units.

To create an array with one or more spares, set or modify the RAID mode using fewer than 5 members, while the spares are disconnected from the Port Multiplier. When EZ mode is enabled, individual drives connected when an array is present are considered spare.

Spare drives must be equal to or larger in size than the smallest member.

When any type of array is defined, individual units will be considered spare. RAID 0 and LARGE arrays are not fault-tolerant and spare drives will not be useful; therefore, disabling EZ for these arrays is recommended.

When a spare drive is present and a fault-tolerant RAID (1, 10, 3, or 5) is defined, EZ mode will automatically rebuild any available spares into the array.

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)

Phone: 408-453-6212

Email: www.addonics.com/support/query/

Image 11
Contents Hours 830 am 600 pm PST Phone Technical SupportArray RAID Rack with Port Multiplier Compatibility Installing drives into the RAID Rack To Mount Back the Top Cover How to Remove the Top CoverThermal Management Card on the RAID Rack Setting or Modifying the RAID Mode Resetting the RAID ModeBZS Switch SW11 RAID 1 or 10 Mirror set, Stripe of mirror sets Jbod Mode Individual DrivesRAID 0 Stripe set Large Spanned set RAID 3 Stripe set with dedicated parityRAID 5 Stripe set with striped parity Clone Mirror setTechnical Support M-F 830am 600pm PST Phone Contact US