DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power
Supplies with Individually Isolated Outputs
Performance/Functional Specifications
Typical at TA = +25°C and VIN =
AC Input |
|
Input Voltage Range, All models ➀ | |
|
|
Input Current (115V/230V, typ.): |
|
0.15A/0.07A | |
0.3A/0.13A | |
0.33A/0.16A | |
|
|
Inrush Current (All models, typical peak): |
|
@115Vac | 14.1A |
@230Vac | 32.5A |
|
|
Isolation (Min.): |
|
Output V1 to AC Input | 3000Vac |
Outputs V2 & V3 to AC Input | 3000Vac + 1000Vdc |
AC Input to Frame Ground | 1500Vac |
Output V1 to Frame Ground | 500Vac |
Outputs V2 & V3 to Frame Ground | 500Vac + 1000Vdc |
Outputs V2 & V3 to Output V1 | 1000Vdc |
Output V2 to Output V3 | 2000Vdc |
|
|
Frame Ground Leakage Current (Max.): |
|
@115Vac | 0.5mA |
@230Vac | 3.5mA |
|
|
Switching Frequency (Typical): |
|
V1 (5W and 10W models) | 75kHz |
V1 (16W models) | 83kHz |
V2 & V3 (All models) | 100kHz |
|
|
Line Fuse | 1A/250Vac, 5 x 20mm, meeting |
for time lag fuses | |
| |
|
|
AC Mains Terminal Block (TB4): | |
Wire Size & Type | |
| solid or stranded |
Insulation Strip Length | 0.25 inches (6.4mm) |
Screw Tightening Torque | 4.4 |
Rated Voltage | 630V (VDE |
250V (VDE |
|
|
|
EMI (All models) | Meets CISPR Pub. 22 & FCC |
Class B |
|
|
|
Safety Approvals | Pending |
|
|
DC Outputs |
|
Line Regulation (All outputs) | ±0.1% (max) |
|
|
Load Regulation: ➁ |
|
V1 (All models) | ±2% |
V2 & V3 (All models) | ±0.2% (max) |
|
|
Output Accuracy (Max.): |
|
V1 (All models) | ±2.0% |
V2 & V3 (All models) | ±2.5% |
|
|
| |
@115Vac | 20mSec. typ. |
@230Vac | 80mSec. typ. |
|
|
Noise & Ripple |
|
(All models, 20MHz bandwidth): | See Noise & Ripple graphs |
V1 | |
V2 & V3 | |
|
|
Transient Response ➂ | See Transient Response graphs |
|
|
DC Outputs (continued) |
|
Efficiency (Typ.@ 120Vac, full load): |
|
Single Output Models | 75% |
Dual Output Models | 73% |
Triple Output Models | 71% |
|
|
Wire Size &Type | |
| solid or stranded |
Insulation Strip Length | 0.25 inches (6.4mm) |
Screw Tightening Torque | 3.6 |
|
|
Short Circuit Protection (All outputs) | Foldback, |
|
|
Overvoltage Protection V1 (max.) | 134% x Vout |
|
|
Environmental |
|
Operating Temperature | 0 to +50°C @ full rated power; |
(see Figure 3) | |
|
|
Storage Temperature | |
|
|
Cooling | Free air convection with derating |
| (see Figure 3 and Technical |
Notes) |
|
|
|
Humidity | 0 to 85% |
|
|
Physical |
|
Dimensions | See Mechanical Specifications |
|
|
Weight: |
|
5 Watt Models | 5.8 ounces (165 grams) |
10 Watt Models | 6.9 ounces (195 grams) |
16 Watt Models | 7.9 ounces (223 grams) |
|
|
Case Materials: |
|
Outer Case | ABS, UL94 5VA |
DC/DC Modules | Phenolic, UL94 |
AC/DC Modules | Plastic, UL94 |
|
|
➀All models will also operate from a regulated and filtered 110 to 340Vdc input.
➁Unless otherwise specified, load regulation is measured with the output under test undergoing a load change of 100% to 50% at nominal line input and, when applicable, with all other outputs operating at 50% of rated load.
➂Transient response is defined as the output returning to within its specified tolerance in 10ms or less, following a 90% load change.
Technical enquiries email: