Patton electronic 3088A quick start Select configuration method, Power up the CPE

Page 3

1.0 Select configuration method

Before powering up, you must select one of the following methods for configuring your OnSite:

Plug ‘n’ Play—The OnSite comes factory-configured for Plug ’n’ Play configuration when connected to a service-provider network.

DIP Switch—For deploying the OnSite in back-to-back applications. To use DIP-switch configuration you must first set the DIP switches to a position other than all OFF or all ON before powering-up the OnSite. To configure your CPE using the DIP switches, refer to the section entitled “Hardware (DIP-switch) configuration” in the OnSite Model 3088A Series Getting Started Guide.

Software Configuration—Allows you to modify configurable parameters by connecting a PC to the con- sole port and issuing software commands. To use software configuration you must set all the DIP switches to the ON position before powering-up the OnSite. To configure your CPE via the console port, refer to section “Software (CLI) configuration” in the OnSite Model 3088A Series Getting Started Guide.

2.0 Power up the CPE

Your G.SHDSL.bis CPE comes with one of the following power supply options:

External AC adaptor with detachable power cord

External DC power supply with terminal block connector (model 48V-PSM3)

2.1 Models with external AC adaptor

1.Connect female plug of the AC power cord to the AC adaptor provided.

2.Connect the barrel-type connector of the AC adaptor to the Power connector on the OnSite.

3.Insert the male plug of the AC power cord into an AC power outlet (100–240 VAC).

2.2 Models with external DC power supply

The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 3088A. The black and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack on the 3088A. (See figure 1).

To Power

Supply Jack

Barrel power connector

MADEINCHINABYSUNNY

S/N:G01234567890

OUTPUTPOWER:5WMAX

OUTPUT:+5V1.0A

INPUT:36-60V0.2AMAX

MODEL:SYD1106-0505

SWITCHINGPOWERSUPPLY

 

To -48VDC

-Vin

Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+Vin

 

Black lead (-V)

Red lead (+V)

Figure 1. DC Power Supply

Model 3088A Series Quick Start Guide

3

Image 3
Contents SHDSL.bis CPE with Fixed Serial Interfaces Model 3088A Series Quick Start Guide Models with external AC adaptor Select configuration methodPower up the CPE Models with external DC power supplyPower up indication Connect the G.SHDSL portConnect the serial port Additional information Compliance Information ComplianceRadio and TV Interference FCC Part EG-Konformitätserklärung Industry Canada NoticeEC Declaration of Conformity Product Description OnSite 3088A SeriesPatton support headquarters in the USA CertificationsCopyright statement Trademarks statementWarranty, Trademark, & Compliance Information
Related manuals
Manual 71 pages 59.37 Kb

3088A specifications

The Patton Electronics 3088A is a highly versatile and robust device designed to facilitate seamless communications over long distances using various transmission mediums. This model exemplifies the pinnacle of technology in the realm of serial-to-Ethernet devices, serving a multitude of applications in modern networking environments.

One of the standout features of the 3088A is its ability to convert RS-232, RS-422, and RS-485 serial signals into Ethernet TCP/IP data packets, allowing for the integration of legacy systems with contemporary Ethernet networks. This feature is crucial for businesses looking to modernize their infrastructure without discarding existing equipment that operates on serial protocols.

The 3088A boasts an impressive transmission range, which makes it suitable for both industrial and commercial applications. It supports data rates of up to 115.2 Kbps, ensuring that data can be transmitted quickly and efficiently. Additionally, with a built-in web server and a user-friendly interface, configuration and management become straightforward tasks, reducing the complexity often associated with network setups.

Another vital feature of the 3088A is its compatibility with various communication protocols, including TCP, UDP, and ARP. This flexibility ensures that it can be integrated into a wide range of network configurations, catering to specific application requirements, from simple point-to-point communication to complex networking setups.

The device also incorporates advanced security features, such as support for secure socket layer (SSL) connections, to safeguard data transmission against unauthorized access and potential threats. This is particularly important in environments where sensitive information is being transmitted, providing peace of mind for organizations concerned about data integrity and security.

Furthermore, the Patton 3088A is designed with durability in mind. It features a compact and rugged enclosure suitable for deployment in harsh environments, making it ideal for field operations and various industrial applications. The device supports wide power input ranges, ensuring operational stability regardless of fluctuating power conditions.

In summary, the Patton Electronics 3088A stands out as a reliable and efficient solution for those seeking to bridge the gap between serial and Ethernet communications. Its high-speed data transmission capabilities, extensive compatibility with various protocols, enhanced security features, and rugged design make it an essential tool for modern networking needs, enabling businesses to evolve while maximizing their existing technologies.