CAUTION! To perform a
The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and charge. All LEDs will be lit. See LED descriptions below to determine the results of the
Note: You can leave connected equipment on during a
CAUTION! Do not unplug your UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into your network connections.
The ON/OFF/TEST Button also functions as a recycle/reset button with sequential outlet startup (including approximately 60 second router outlet delay) for proper modem and router rebooting.
2“ON/OFF” LED: This green LED lights continuously to indicate that the UPS is ON and supplying your equipment with AC power either from a utility source or from the UPS’s internal batteries.
3“OVERLOAD/CHECK BATTERY” LED: This red LED lights continuously after a
CAUTION! Any overload that is not corrected by the user immediately following a
4Battery Backup Protected/Surge Protected Outlets: These four outlets provide both battery backup and surge protection. Plug your modem, router, RF amplifier and other equipment into these outlets. The outlet labeled "ROUTER" features a delay start function. This outlet will turn on approximately 60 seconds after the unit powers up. Use this outlet for a router or any other device you wish to start up approximately 60 seconds after other connected equipment.
5Tel/DSL Line Protection Jacks: These jacks protect equipment against surges over a single phone line. Select models feature a
6
7Resettable Input Circuit Breaker: Protects your electrical circuit from overcurrent draw from the UPS load. If this breaker trips, remove some of the load, then reset it by pressing it in.
8Regulated 12V DC Connector: This connector provides an additional power source for 12V DC devices. It features
a delay start function and will turn on approximately 60 seconds after the unit powers up. NOTE: Observe polarity
Steps for proper wiring of male connector:
1.Strip wire to appropriate length.
2.Insert small screwdriver into slot on crimping button.
3.Insert wire into the hole.
4.Release screwdriver.
Storage and Service
Storage
To avoid battery drain, all connected equipment should be turned off and disconnected from the UPS. Press and hold the ON/OFF/TEST switch for one second. Your UPS will be completely turned off (deactivated), and will be ready for storage. If you plan on storing your UPS for an extended period, fully recharge the UPS batteries every three months. Plug the UPS into a live AC outlet, turn it on by pressing and holding the ON/OFF/TEST switch for one second, and allow the batteries to recharge for 4 to 6 hours. If you leave your UPS batteries discharged for a long period of time, they will suffer a permanent loss of capacity.
3