input voltage range of
Includes a total of 6
Includes 1 USB and 1 DB9 monitoring port for remote monitoring of UPS status and site power conditions
Communications ports enable safe unattended shutdown without data loss during extended power failures
Communications ports support messaging of UPS and line power status, including
Communications ports support timed inverter shutoff after unattended shutdown, activate
PowerAlert UPS monitoring and unattended shutdown software with complete cabling included
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting completely locked computers by automatically switching UPS power off and back on again
Notification of system status via 5 LEDs and
Wall mountable with UPSWM wallmount bracket
Attractive small footprint beige tower housing uses less than 66 square inches
Cold start capability enables UPS
UL (USA), cUL (Canada), NOM (Mexico), Class A (Emissions)
$250,000 Ultimate Lifetime Insurance (USA and Canada only)
2 year manufacturers product warranty with $250,000 connected equipment insurance (USA & Canada Only)
Specifications
SYSTEM OVERVIEW
Voltage compatibility | 120V AC |
|
|
Frequency | 60 Hz |
compatibility |
|
|
|
OUTPUT |
|
Output VA | 1500 |
|
|
Output watts | 980 |
|
|
Output nominal | 120V AC |
voltage |
|
|
|
Output voltage | LINE MODE: Sine wave line voltage 120V |
regulation | BATTERY MODE: PWM sine wave output 115V |
|
|
Output frequency | LINE MODE: Passes line frequency of 60Hz |
regulation | BATTERY MODE: Inverter output regulated to 60Hz |
|
|
Outlet quantity / type | 6 NEMA |
|
|
Customized load | "Individually controllable outlet supports load shedding and remote reboot on demand of locked network devices. |
management | Controllable via PowerAlert software to switch off optional loads, like monitors, to increase available runtime for servers |
receptacles | and other critical devices." |
|
|
Overload protection | Circuit breaker |
|
|
INPUT |
|
Maximum input amps | 12A / 1070 watts |
|
|
Input connection type | NEMA |
|
|
Input cord length | 6 ft., 14 gauge |
|
|
Recommended | 15A 120V |
Electrical Service |
|
|
|
BATTERY |
|
Full load runtime | 7 minutes (1500VA) |
|
|
Half load runtime | 20 minutes (750VA) |
|
|
DC system voltage | 36 V DC |
|
|
Typical battery | |
lifespan |
|
|
|