Features

120V 30A maximum capacity (agency de-rated to 24 amps) Switched, Metered and Monitored Power Distribution Unit (PDU) with built-in web/network interface in 0U vertical rack form factor

Includes attached L5-30P input plug and 24 x 5-15/20R controllable outlets arranged in two 12-outlet load banks

Supports individually controllable output receptacles, current metering, network monitoring and remote control via built-in Web/network monitoring and control card

Provides the ability to turn on, turn off, recycle or lock out power to each individual PDU receptacle on a programmable or real-time basis Switchable outlets enable a number of advanced networking abilities, such as remote reboot on-demand of locked IT equipment, custom power-on/power-off outlet sequencing, automatic load shedding of optional loads during power failures and disabling unused outlets to prevent the connection of unauthorized equipment loads

Remote interface provides data regarding input power conditions, load level and individual outlet power status via secure network or web browser interface

Supports notification and logging of all major power events and user-specified alarm thresholds

Optional ENVIROSENSE temperature and humidity probe enables remote monitoring of environmental conditions and the ability to report conditions from up to two contact-closure sensors

Optional ENVIROSENSE probe also supports the connection of up to three user-supplied contact-closure sensors to selectively notify, monitor and log reported conditions, such as rack door access

DHCP/Manual configuration support enables network settings to be automatically assigned to the card, or manually assigned via permanent IP addresses

10/100 Mbps auto-sensing allows optimal communication compatibility with your current 10/100 Base-T network

Real-time clock support maintains the time of day and date even if the PDU is shut down and unpowered

2-tier level access enables an administrator and a guest to log into the web browser for monitoring and/or management of all intelligent PDUs and similarly equipped UPS systems

Alert notifications via email or SNMP traps provide immediate event notification

Protocols supported include HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, FTP, DHCP,

BOOTP, NTP

Front panel ammeter with pushbutton toggle switch displays power consumption for all three loading segments (12 outlets in bank 1, 12 outlets in bank 2 and total load of banks 1 and 2 combined)

On initial power-up, outlets are automatically energized at 250 millisecond intervals to prevent inrush-related equipment interaction and mains circuit overloads

Each 12-outlet bank is protected by a separate 20A circuit breaker

Included cord retention brackets keep vital network equipment plugged in and continuously powered

70-in. 0U vertical rack installation supported with included rackmount brackets

Tooless mounting supported in button-mount compatible racks

Specifications

SYSTEM OVERVIEW

Voltage compatibility

120V

 

 

Frequency

50/60 Hz

compatibility

 

 

 

OUTPUT

 

Output nominal

120V

voltage

 

 

 

Outlet quantity / type

24 x 5-15/20R

 

 

Customized load

Each outlet is individually controllable via remote interface

management

 

receptacles

 

 

 

Overload protection

INPUT

Outlets are arranged in two separately breakered 20A banks. 12 upper outlets are protected by the upper circuit breaker; 12 lower outlets are protected by the lower circuit breaker

Maximum input amps

30A maximum (Agency de-rated to 24A continuous)

Input connection type

Attached L5-30P input plug

Input cord length

10 ft./3m

Image 2
Contents Highlights DescriptionSystem Overview FeaturesSpecifications OutputRelated Items Envirosense Snmp AccessoriesSRCABLERING1U SRCABLEDUCT1U

PDUMV30NET specifications

Tripp Lite PDUMV30NET is a versatile and robust power distribution unit (PDU) designed to meet the demands of high-performance data centers, server rooms, and network environments. This unit stands out due to its advanced features and capabilities that ensure efficient power management and reliable distribution.

One of the key features of the PDUMV30NET is its ability to support a wide range of input power configurations. With a 30 amp capacity and a 3-phase input, this PDU can accommodate various power requirements while enabling seamless integration into existing electrical systems. This flexibility is essential for facilities that utilize different power configurations, allowing for tailored solutions that optimize performance.

The unit also boasts multiple outlet options, including NEMA L6-30R outlets, which facilitate the connection of multiple devices and equipment. This multi-outlet configuration not only maximizes the use of available power but also allows for the efficient distribution of energy to critical devices. Additionally, the PDUMV30NET features a built-in network interface, enabling remote monitoring and control of power usage through a web-based interface. This capability allows IT professionals to track real-time power consumption, set alerts, and manage loads effectively, enhancing overall operational efficiency.

The PDUMV30NET is designed with reliability in mind, featuring a rugged metal chassis that ensures durability and protection against any potential damage. Its compact design allows for easy mounting in racks and cabinets, saving valuable space in crowded data center environments. Furthermore, the unit includes surge protection to safeguard connected equipment from power surges and spikes.

Another significant characteristic of the PDUMV30NET is its compliance with various safety standards and regulations. This ensures that the unit operates safely within different environments while providing peace of mind to users. With features like a built-in circuit breaker and LED indicators for power status, users can monitor and manage the power distribution easily.

In conclusion, the Tripp Lite PDUMV30NET PDU excels in providing reliable power distribution, monitoring capabilities, and safety features, making it an essential component for modern data centers and networking environments. Its robust design and flexibility make it suitable for various applications, ensuring that critical equipment remains powered and operational.