Tripp Lite OMNI1500XLNAFTA warranty Specifications, System Overview, Output, Input, Battery

Page 2

USB port and cable enables UPS monitoring and unattended shutdown in the case of extended power failure

PowerAlert software available via free download from www.tripplite.com

Data line surge suppression protects standard dialup/DSL or Ethernet line connection

Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and overload

1500VA power handling ability supports a variety of sensitive electronic equipment

4.5 minutes full load runtime (1500VA), 13 minutes half load runtime (750VA)

Runtime is expandable with the addition of external battery packs (SEE OPTIONS & ACCESSORIES)

Supports hot swappable battery replacement via built-in access panel

$200,000 connected equipment insurance (USA, Puerto Rico & Canada Only) 2 year warranty

Specifications

SYSTEM OVERVIEW

Voltage compatibility

120V AC

 

 

Frequency

60Hz

compatibility

 

 

 

OUTPUT

 

Output VA

1500

 

 

Output watts

940

 

 

Output nominal

120VAC

voltage

 

 

 

Output voltage

LINE MODE: Sine wave line voltage 120V (-18% / +8%), BATTERY MODE: PWM sine wave output 120V +/-5%

regulation

 

 

 

Output frequency

LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz

regulation

 

 

 

Outlet quantity / type

8 NEMA 5-15R

 

 

INPUT

 

Maximum input amps

12A

 

 

Input connection type

NEMA 5-15P

 

 

Input cord length

6 ft., 14 gauge

 

 

Recommended

15A 120V

Electrical Service

 

 

 

BATTERY

 

Full load runtime

4.5 minutes (1500VA / 940 watts)

 

 

Half load runtime

13 minutes (750VA / 470 watts)

 

 

Expandable battery

Extended runtime available with optional BP24V34, BP24V15RT2U, BP24V28-2U or BP24V70-3U external battery

runtime

packs

 

 

DC system voltage

24VDC

 

 

Typical battery

3-6 years, depending on usage

lifespan

 

 

 

Battery recharge rate

2-4 hours to 90%

Replacement Battery

RBC51 (quantity 2)

Cartridge

 

 

 

VOLTAGE REGULATION

 

Voltage regulation

Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without

description

using battery power, during brownouts to 75V and overvoltages to 147V

 

 

Overvoltage

Input voltages between 128 and 147VAC are reduced by 12%

correction

 

 

 

Direct pass through

Input voltages between 108 and 127VAC are passed on to connected equipment unchanged

Image 2
Contents Description FeaturesHighlights System Overview SpecificationsBattery OutputSurge / Noise Suppression Leds Alarms & SwitchesLine / Battery Transfer PhysicalRelated Items Special FeaturesWarranty CertificationsTripp Lite. All Rights Reserved