Tripp Lite owner manual Rackmount Installation, Wallmount/Under Counter Installation

Page 1

Owner’s Manual

Rackmount Power Strips and Isobar®

Rackmount Surge Suppressors/

Line-Noise Filters

Designed to Occupy One Standard 19 in. Rack Space

Español: p. 5 • Français: p. 9

IMPORTANT SAFETY INSTRUCTIONS. This manual contains information concerning the proper installation and use of Tripp Lite’s Rackmount Power Strips and Isobar Surge Suppressors. SAVE THESE INSTRUCTIONS.

Devices with surge protection feature an internal protection that will disconnect the surge protective component at the end of its useful life but will maintain power to the load—now unprotected.

(IBAR12, ISOBAR12ULTRA, RS-1215, RS-1215-RA, RS-1215-HG, DRS-1215): DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from each AC outlet. DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from all the outlets combined.

(IBAR12/20ULTRA, IBAR12-20T, RS-1215-20): DO NOT exceed the MAXIMUM LOAD of 15 amps that can be drawn from each AC outlet located on the front of the IBAR12/20ULTRA and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that can be drawn from each AC outlet on the RS-1215-20, or each AC outlet located on the rear of the IBAR12/20ULTRA and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that can be drawn from all the outlets combined.

Rackmount Installation

To Mount Unit in Rack: Put four user-supplied rackmount screws (A) through the unit’s mounting ears (B) and into the rack rails as shown. The user must determine the fitness of the rackmount screws to hold the unit in the rack before installation.

Wallmount/Under Counter Installation

1. Detach Mounting Ears: Unscrew the screws (A) holding the unit’s mounting ears (B) to the sides of the unit.

2. Reorient Mounting Ears: Use the screws from Step 1 (A)

 

to reattach the mounting ears (B) to the unit as shown.

 

Use only the manufacturer-supplied screws or their

 

equivalent (#6-32, ¼" flat head) to reattach the mounting

 

ears. The screws should be put through diagonally

Step 1

opposite holes on the ear.

 

3.Mount Unit on Surface: Put four user-supplied screws

(C)or similar mounting hardware through the unit’s mounting ears (B) and into the mounting surface as shown. The user must determine the fitness of the user- supplied mounting hardware to support the unit before mounting.

Steps 2 & 3

Image 1
Contents Wallmount/Under Counter Installation Rackmount InstallationSpecifications FeaturesIlluminated On/Off Switch All Models Diagnostic Indicator Lights Isobar Models OnlyManual de Operación Limited Lifetime WarrantyUltimate Lifetime Insurance Policy Instalacion en Bastidor o RackEspecificaciones CharacteristicasBancos de Filtros Aislados y Circuito en Cascada Fixation Mural/Installation Sour Un Comptoir Installation Sur BatiGuide de ’utilisateur Garantía Limitada para la Vida Útil del EquipoCommutateur « ON/OFF » Illuminé tous les modèles CaracteristiquesCircuits des Blocs et Cascades de Filtres Isolés Assurance Ultime á Vie Garantie Limitee á Vie

Rackmount Power Strips and Isobar Rackmount Surge Suppressors/ Line-Noise Filters specifications

Tripp Lite, a leading provider of power protection and connectivity solutions, offers an impressive range of rackmount power strips and Isobar rackmount surge suppressors/line-noise filters. These products are essential for any organization that demands reliable and efficient power management in their data centers, server rooms, or telecommunications setups.

One of the standout features of Tripp Lite rackmount power strips is their robust construction. Built to be durable, these power strips are designed to withstand the rigors of everyday use in professional environments. They come with multiple outlets to accommodate a variety of devices, ensuring that all critical equipment can be powered simultaneously. With a wide range of configurations available, users can select the ideal model to match their specific power requirements.

In terms of technology, Tripp Lite employs advanced components in their Isobar rackmount surge suppressors. Each Isobar unit is equipped with high joule ratings, which means they can absorb a significant amount of energy from electrical surges, protecting vital equipment from damage. The surge suppressors also feature noise filtering capabilities, which reduce electromagnetic interference (EMI) and radio frequency interference (RFI). This is particularly important in data processing environments, where even minor fluctuations can cause data corruption or performance degradation.

Tripp Lite's surge suppressors incorporate a patented isolating filter technology. This isolation effectively prevents interference between connected devices, ensuring cleaner power delivery. Each unit includes a resettable circuit breaker that provides overload protection, enhancing overall safety during operation.

Another key characteristic of Tripp Lite power strips and surge suppressors is their compliance with industry standards. Many models meet or exceed UL 1449 surge suppression testing standards, which assures users of their reliability. Additionally, Tripp Lite offers models with vertical and horizontal mounting options, making installation flexible according to rack configuration.

To further enhance user experience, many of these power strips and surge protectors come with LED status indicators that provide real-time feedback on power availability and surge protection status. This feature is especially beneficial for quickly identifying potential issues within power management systems.

In conclusion, Tripp Lite rackmount power strips and Isobar surge suppressors/line-noise filters are essential tools for any enterprise that values robust power management. With their durable construction, cutting-edge technology, and focus on safety, these products deliver the reliability and performance necessary to keep critical systems running smoothly.