Specifications

GENERAL

Construction

 

Back Box

Aluminum

Dome Drive

Aluminum, thermoplastic

Lower Dome

Clear polycarbonate, 0.090-inch

 

thick

Cage Thickness

0.12 x 0.30-inch cast stainless

 

steel

Cage Color

Black, for maximum discreetness

Cable Entry (Back Box)

0.75-inch conduit fitting

Pan Movement

360° continuous pan rotation

Vertical Tilt

+2° to -92°

Manual Pan/Tilt Speeds*

 

Pan

0.1°- 80°/sec manual operation,

 

150°/sec turbo

Tilt

0.1°- 40°/sec

Preset Speeds

 

Pan

400°/sec

Tilt

200°/sec

Environment

Indoor only

Operating Temperature

32° to 122°F (0° to 50°C)

Weight (approximate)

 

Back Box

2.17 lb (0.98 kg)

Dome Drive

3.30 lb (1.48 kg)

Lower Dome

0.20 lb (0.09 kg)

In-Ceiling

1.60 lb (0.73 kg)

In-Ceiling with Cage

3.60 lb (1.63 kg)

ELECTRICAL (Dome Drive Only)

Input Voltage

18–32 VAC; 24 VAC nominal

 

22–27 VDC; 24 VDC nominal

Input Power

 

24 VAC

23 VA nominal (indoor, without heater)

24 VDC

0.7 A nominal (indoor, without heater)

Fuse

1.25 A

Auxiliary Outputs

2 (Spectra IV SE only)

Alarm Inputs

7 (Spectra IV SE only)

*For variable-speed operation, an appropriate controller is required. With fixed-speed controllers, pan/tilt speed is 20°/sec. The CM6700/CM6800 controller with the KBD200A keyboard has programmable fixed speeds.

C3419M-D (11/08)

13

Image 13
Contents Heavy Duty Spectra IV Series Installation AC/DC C3419M-D 11/08 C3419M-D 11/08 Switch 1 Dome Drive TroubleshootingSpecial Systems Switch SettingsTable F. Switch Settings for SW1, P-Type Control 100 111 191 General SpecificationsALL Others are Inches Product Warranty and Return Information