Q-Logic 4100 Installation, Environmental, Specifications, Condition Environment, Temperature

Page 10

QuickSpecs

HP StorageWorks EVA iSCSI Connectivity Option

Technical Specifications

 

Multi-Path support

HP OpenVMS

Native

 

 

Windows

Microsoft MPIO

 

 

Linux

Device Mapper

 

 

Sun

MPxIO

 

 

VMware

Native software MPxIO

 

Max. Pending Commands

Default value of 64.

 

 

Host Interface

Uses standard TCP/IP connection, RJ45 connector

 

Distance

GbE Copper, CAT-5e or CAT-6, twisted pair

 

Host Platform Support

Any 32-bit or 64-bit servers running the supported OS

 

Performance

half duplex

>30,000 > 200 MB / Sec

 

 

full duplex

> 360 MB / Sec

 

Maximum Host

Architectural Limits

 

 

Connection Design Limits

256 connections per iSCSI port

 

 

for iSCSI*

mpx100b is limited to 16 iSCSI initiator ports in base unit. License upgrades

 

 

are available in two steps, a 32 initiator license followed by an unlimited

 

 

license up to the HP supported maximum.2 FC target ports, with maximum

 

 

initiators

 

 

 

* Please see the product user guide available on the Storage Networking

 

 

product page and the SAN Design Guide for latest tested and supported

 

 

configurations located at: http://www.hp.com/go/sandesignguide.

Installation

User installable, but recommended field service install

 

Environmental

Optional side-by-side 1U rack mount kit

 

Specifications

Non-cable-side to cable-side airflow; power from cable-side; 1U, 19-in. EIA rack-compliant

 

Cooling: Two fans with back-to-front airflow

 

 

 

Condition

 

 

Environment

Operating1

Non Operation2

 

Temperature

5° to 40° C

-25°C to 70° C

 

 

(41° to 104° F)

(-40° to 158° F)

 

Humidity3

5 to 90%, non-condensing

5 to 93%, non-condensing

 

Altitude

3 km

15 km

 

Shock

IEC 68-2, 4g, 11ms, 20 repetitions

IEC 68-3, 30g, 292 ips, 3 repetitions,

 

 

 

3 axis

 

Vibration4

IEC 68-2, 5-500Hz, random, 0.21G

IEC 68-2, 5-500Hz, random, 2.09G

 

 

rms, 10 minutes

rms, 10 minutes

 

Power AC input Nominal

Power AC input Nominal: 0.5A@100-125 VAC 0.25A@200-240 VAC

 

Frequency Range

47 to 63 Hz

 

Nominal Frequency

50 Hz to 60 Hz

 

Range

 

 

 

Power Dissipation

48W maximum (optics included)

1Environmental specification for operating condition should be satisfied before the iSCSI Connectivity Option subsystem is powered on. Maximum temperature of 40°C should be strictly satisfied at air inlet portion.

2Non-operating condition includes both packing and unpacking conditions unless otherwise specified.

3No condensation in and around the iSCSI Connectivity Option should be observed under any conditions.

4The above specifications of vibration are applied to all three axes.

On shipping/storage condition, the product should be packed with factory packing.

DA - 12413 Worldwide — Version 10 — June 19, 2009

Page 10

Image 10
Contents QuickSpecs OverviewKey Features HP StorageWorks EVA ModelsConnectivity Option Mpx100 ISCSI ConnectivityProduct Highlights Command ViewSoftware Components, Standard ManageabilityService and Support, HP Care Pack and Warranty Information QuickSpecs Additional Options Base Configuration and Power PackConfiguration Information Model Model DescriptionLC-SC for between a 1 Gb and a 2 Gb device Gb optical cables LC-LC for between two 2 Gb devicesFC Copper cables Technical Specifications Temperature InstallationSpecifications Range Power DissipationPhysical Size