Software Installation
added, the system will prompt you to take care of port configuration, which is discussed in this section.
1.Click on a specific port from the CP-168U Series Installation window, and then click on [Port Setting] to open the Port X dialog box.
2.Select a COM number for the port from the Port Number pull-down list.
3.Check the Auto Enumerating COM Number check-box to have subsequent ports mapped to continuous COM numbers. For example, if COM 3 is assigned to Port 1, then COM 4 will be automatically assigned to Port 2.
4.Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger levels from High to Low are available, with a default value is High Level (120 bytes). Check Set the change to all ports check-box to apply the just defined Rx FIFO Trigger to all ports.
5.Select a Tx FIFO Size from the Tx FIFO Level pull-down list. Tx FIFO Level from High to Low are available, with a default value is High Level (128 bytes). Check Set the change to all ports check-box to apply the just defined Tx FIFO Size to all ports.
Smartio CP-104UL User’s Manual 3-15