Moxa Technologies C168H user manual Configuring Board and Port, Re-configure Port Setting

Page 26

Configuring Board and Port

Re-configure Port Setting

If the driver is installed and only desire to re-configure the ports, please refer to the following procedures. Except procedures listed below, it is also allowed to do so by clicking [Start] è [Program Files] è [MOXA Utility] è [Moxa Smartio/Industio Configuration Panel] è [Property] and then refer to Step 6-21 in the previous section “First Time Installing Driver” of “Windows NT” section.

1.Open [Control Panel], click [Network] icon and select [Adapters] tab.

2.Click on MOXA Smartio/Industio Family Adapter in Network Adapters list

3.Click [Properties] button to open Moxa Smartio/Industio Configuration Panel dialog box to change port setting and advanced FIFO configuration.

3-8Smartio C168H/PCI User’s Manual

Image 26
Contents Smartio C168H/PCI User’s Manual Smartio 8 Ports Serial Board for PCI Bus Jul 2nd EditionDisclaimer Copyright NoticeTrademarks Moxa Internet Services About This Manual Table of Contents Technical Reference Board Applications Smartio The Smart Multiport Async SolutionsOverview Operating System Support FeaturesPCI Solution Moxa Serial Comm ToolWindows NT and Windows 95/98 ¡Ñ1 Check ListOpt8A/Opt8B/Opt8S Opt8J Opt8C/Opt8DOpt8F/Opt8Z Option Opt8x and Cable Wiring for cable wiring Installation GuideInstallation Programming Tools6Smartio C168H/PCI User’s Manual Hardware Installation Installing the Smartio C168H/PCI BoardInstalling Connection Option Opt8x Hardware Installation Opt8J/Opt8F/Opt8Z Operating Opt8JRS-422 Mode RS-485 Mode6Smartio C168H/PCI User’s Manual Software Installation Windows NTInstalling Driver First Time Installing DriverSoftware Installation Page Page Page Moxa Smartio/Industio series board! pops up, refer to Configuring Board and Port Re-configure Port SettingSoftware Installation Add Another C168H/PCI Board Configuration Remove Existing C168H/PCI Board Configuration Updating DriverRemoving Driver Windows 95/98 See Section Board and Port Ready Stage See Section First Time Driver Installation StageSee Section Port Configuration Stage First Time Driver Installation Stage Page Port Configuration Stage Page Page Board and Port Ready Stage Port1=COMx interrupt number is invalid! pops up, refer toSelect Ports Configuration tab Page Click on Moxa C168 PCI Series and click Properties button Page Removing driver Click OK button in Add/Remove Programs Properties dialog box PComm Installation Windows NT and Windows 95/98 consistingPComm Programming Library UtilityDiagnostic for Moxa boards only Lite and DiagnosticMonitor for Moxa boards under Windows NT Only Terminal Emulator Solution RS-485 Programming for Opt8JSend data 8Smartio C168H/PCI User’s Manual Connection Option Opt8x & Cable Wiring RS-232 Cable Wiring for Opt8A/B/C/D/SCTS RTS DTR GND DCD Type 1 To connect Smartio C168H/PCI to a DTE device Type 2 To connect Smartio C168H/PCI to a DCE device Opt8D DB9 Male GND RTS CTS DTR DST DCD GND RTS CTS DTR DSR DCD RS-422 Cable Wiring for Opt8J/F/Z Opt8J onlyGND RTS+B CTS+B RS-485 Cable Wiring for Opt8J RS-422/485 Impedance Matching 12Smartio C168H/PCI User’s Manual Troubleshooting General TroubleshootingSoftware Causes and Solutions Windows NT system panic blue screen System fails to find the Smartio C168H/PCI board4Smartio C168H/PCI User’s Manual Specification Technical ReferenceUart 16C550C DB62 Connector Pinouts 4Smartio C168H/PCI User’s Manual Operating System o DOS PCI IRQ Configuration in BiosMoxa Driver version Return Procedure