Network Technologies KEEMUX-Px operation manual Configuration, Cascaded Installation

Page 10
VEXT-xx-MM
5VDC
2A

NTI KEEMUX Series PS/2 KVM Switch

Configuration

All 4, 8, and 16-port units are configured using the 8-position dip-switch (located on the front of each unit) according to tables 1 and 2 below.

Front Panel Configuration Switches

Table 1 * (default settings)

Switch

SW1

SW5

SW6

STAND-ALONE SWITCH

OFF*

OFF*

OFF*

SLAVE

ON

OFF

OFF

MASTER W/4-PORT SLAVES

OFF

OFF

ON

MASTER W/8-PORT SLAVES

OFF

ON

OFF

MASTER W/16-PORT SLAVES

OFF

ON

ON

Table 2 * (default settings)

Master & Slave SW2-4 Settings

SW2

SW3

SW4

Master with-

Slave Setting

OFF*

OFF*

OFF*

No Slave Attached

N/A

OFF

OFF

OFF

1

Slave attached

Slave Unit #1

OFF

OFF

ON

2

Slaves attached

Slave Unit #2

OFF

ON

OFF

3

Slaves attached

Slave Unit #3

OFF

ON

ON

4

Slaves attached

Slave Unit #4

ON

OFF

OFF

5

Slaves attached

Slave Unit #5

ON

OFF

ON

6

Slaves attached

Slave Unit #6

ON

ON

OFF

7

Slaves attached

Slave Unit #7

ON

ON

ON

8

Slaves attached

Slave Unit #8

About Table 2:

These switch settings are used by the slave(s) to establish its identity (i.e. location in the group) to the master.

On a master, the same switches are used to configure the master for how many slaves are attached to it.

Cascaded Installation

1.Attach all slaves consecutively to the master switch.

a.Perform steps 1 and 2 under INSTALLATION on page 4 for each slave unit.

b.Configure each switch as per the tables above under CONFIGURATION before proceeding.

c.With a VEXT-xx-MM cable, connect slave #1 monitor port to master’s VIDEO 1 port.

d.With a VVKINT-xx-MM or (2) VKEXT-xx-MMs, connect slave #1’s PS/2 DEVICES ports to the master’s CPU1 KEYBOARD and MOUSE ports.

e.Repeat steps c and d for each additional slave unit, keeping in mind that each slave will connect to the next available master’s port (i.e. slave #2 to master’s VIDEO 2 and CPU 2 KEYBOARD and MOUSE, etc.). See Fig. 5 below.

If additional 4-PORT slaves are connected to VIDEO, PS/2 MOU CPU, & PS/2 KBD CPU ports 3 & 4, they will function and be controlled as CPU ports 9-12 and 13-16 respectively.

- OR-

If individual CPUs are connected

to ports 3 & 4, they will function and be controlled as CPU ports 9 & 10 respectively.

- +

MASTER UNIT (KEEMUX-P4)

CONNECT SLAVES FOR CASCADED

CPU CONNECTIONS

 

 

CPU 5-8

CPU 1-4

 

NTI

 

I

I

I

I

N

 

R

V

V

V

V

M

 

 

 

 

 

 

 

O

 

 

 

D

D

D

D

I

 

1275 Danner Dr

 

E

E

E

E

 

Aurora, OH 44202

T

 

O

 

O

O

O

 

www.nti1.com

 

 

 

2

 

R

 

Tel:330-562-7070

 

 

 

 

 

 

 

-562-1999

 

C

C

C

 

C

Mouse

 

 

Keyboard

 

P

 

P

 

 

 

 

 

 

 

Daisy

 

U

 

U

 

U

 

 

 

 

 

Out

 

4

3

2

 

1

 

 

 

 

 

 

CPU 4

CPU

2

CPU 1

PS/2 DEVICES

 

 

CPU 7

CPU 5

 

 

 

 

 

CPU 3

CPU 1

 

 

 

 

 

 

CPU 8

CPU 6

 

 

 

 

VVKINT-xx-MM

CPU 4

CPU 2

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

R

 

 

 

 

 

 

M

 

 

 

 

 

 

M

 

 

 

 

V

V

V

V

 

 

 

V

V

V

V

 

 

 

 

I

I

I

I

O

 

 

 

I

I

I

I

 

1275 Danner Dr

 

 

D

D

D

D

 

1275

Dr

 

D

D

D

D

I

 

 

E

E

E

E

T

Aurora,

44202

 

E

E

E

E

T

Aurora, OH 44202

 

 

O

O

O

O

www.

.com

 

O

O

O

O

O

www.nti1.com

 

 

O

 

 

 

 

 

 

 

4

3

2

1

R

Tel:330-

-7070

 

4

3

2

1

R

Tel:330-562-7070

 

 

 

 

 

 

 

-

-1999

 

 

 

 

 

 

Fax:330-562-1999

 

 

C

C

C

 

C

 

 

 

 

C

C

C

 

Mouse

 

 

 

 

Keyboard

 

 

 

P

Keyboard

 

 

5VDC

P

P

P

 

P

 

5VDC

 

P

P

P

 

 

 

Daisy

 

 

 

 

 

 

Daisy

Daisy

-

2A

U

U

U

 

U

Out

-

2A

 

 

U

U

U

Out

In

+

4

3

2

 

1

 

+

 

 

3

2

1

 

 

 

 

CPU 4

CPU 3

CPU 2

CPU 1

PS/2 DEVICES

 

 

 

CPU 4

CPU 3

CPU

 

DEVICES

 

SLAVE UNIT #2 (KEEMUX-P4)

SLAVE UNIT #1 (KEEMUX-P4)

For connection of CPUs 5-8

For connection of CPUs 1-4

Figure 6- Cable connections for cascading

6

Image 10
Contents KEEMUX-Px MAN077 Rev Date 7/1/2007 Table of Contents Table of Figures Available Options IntroductionMaterials LimitationsFeatures and Functions Prepare To Connect InstallationMake Connections AT Style Connector Rear View of KEEMUX-P8Cascading Power UpLimitations Configuration Cascaded InstallationUsing the NTI Keemux PS/2 KVM Switch Front Panel ControlKeyboard Control Basic Command ModeCommand Functions Keystroke Increment Port Keyboard CtrlBroadcast Mode Scan ModeNormal Mode OSD Control Enabling the Security FeatureUser Login Mode Security OptionAdditional Modes Available With Security Administration ModeUser Name List OSD Command Mode User Access FunctionsSystem Access List Keystroke Ctrl + S Ctrl + B Ctrl + E Ctrl + MOSD Command Mode Contd FunctionKeystroke Press Ctrl for more functionsEdit Mode Erase previous characterMaintenance Mode Search ModeEsc Enter Maintenance Mode Cont’d FunctionKeystroke Help ModeActivate security features Remote Connection RS232 Connections and ConfigurationBaud Rate RS232 Matrix-Y-1 CPU Serial Port Wiring Schematic of Matrix-Y-1 cableUnit Address and Loop Back First Unit Second Unit Last UnitResponse Command ProtocolFormat RS Aacr Format CS AA,XX,YYCRFormat RO AA,XXCR Keyboard MappingFormat RU Aacr HOW to Disable Operating Modes For models KEEMUX-Pxin a plastic caseOverhead view of inside of Keemux Kcmd Configuring The Jumper BlockDDC Support BrdcDual Video Support Audio SupportOptional- 4 port models only Troubleshooting Problem No Video