Installing the Replacement Power Entry Module in the 8820 BAC
Procedure
1.Apply the supplied
2.Fasten the #8 AWG wires, with their ring tongue terminals properly installed, to the power taps using the M4
—Connect the negative wire to the power tap on the right (48V NEG is printed on the front of the PEM’s faceplate).
—Connect the return or positive wire to the power tap on the left (48V RTN is printed on the front of the faceplate).
Tighten the M4 screws securely to the power taps while keeping the ring tongue terminals and their wires dressed parallel to the board and perpendicular to the faceplate.
3.Feed and dress the power wires through the notched holes at the top of the PEM’s faceplate.
4.Slightly spread open the split cable bushings and slip them over each wire and into the holes at the top of the faceplate. Press on the cable bushing to snap it into the faceplate.
5.Slide the PEM into the chassis using the nylon card guides.
6.Secure the PEM to the chassis using the mounting screws removed from the PEM.
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
—Within the U.S.A., call
—Outside the U.S.A., call
.
Copyright © 2004 Paradyne Corporation. Printed in U.S.A.
4 | October 2004 |