3 Options:

Half Duplex

-RTS

-DTR

MUX

16C550

 

Data Out

RS-422/485

 

+

 

Driver

 

-

 

 

 

 

Active Low

Output Enable

Aux Out

Full Duplex

RS-422/485

+

Driver

-

NOTE: One of these three options must be selected via software configuration. Full duplex operation is the default mode.

Figure 8. RS-422/485 Driver Enable Options

If RTS is selected as the signal to enable the output drivers, setting 'bit 1' of the Modem Control Register (to logic '1') will enable the output drivers and clearing 'bit 1' of the Modem Control Register (to logic '0') will force the outputs into a high impedance state.

Similarly, if DTR is chosen as the signal to enable the output drivers setting 'bit 0' of the Modem Control Register (to logic '1') will enable the output drivers and clearing 'bit 0' of the Modem Control Register (to logic '0') will force the outputs into a high impedance state.

Selection of half duplex mode operation is dependent upon the configuration software and/or the operating system used. Each of these,

however, ultimately control the half duplex mode by accessing the PCMCIA Configuration Register on the QSP-200/300.

CAUTION:

When operating in half duplex mode, the transmitter output drivers must be disabled before receiving and information. Failure to do so will result in two output drivers being connected together which may cause damage to the adapter, the computer, and/or the peripheral equipment.

QSP-200/300 User's Manual

39

Image 45
Contents Interface Cards for Personal Computers Warranty Information QSP-200/300Product Description Four Channel RS-422/485 Pcmcia Adapter Trademarks Compliances Electromagnetic Emissions EC Council Directive 89/336/EECFCC Class B Table of Contents This Page Left Blank Intentionally Introduction Windows 95/98/ME/2000/NT Installation Windows 95/98 Window Millennium MEWindows Installing QSP-200/300 Under Windows NT Page Page Page Window 95/98/ME Page Windows 95/98/ME Changing Configuration of the QSP-200/300Page IRQ Windows CE 1Installing Quatech Pcmcia Cards under Windows CEPage DOS / Windows 3.x Installation QSP-200/300 Client Driver for DOS Client Driver InstallationBaddress Command Line OptionsDTR Controlled Example QSP-200/300 Client Driver ExamplesDevice = C\QSP-200\QSP200CL.SYS i5,h,u,b300,o2 Device = C\QSP-200\QSP200CL.SYS s0,b300,i5 s1,b340,i10,o1 Common Problems Generic Client Drivers QSP-200/300 Enabler for DOSMultiple Configuration Attempts Older Versions of Card and Socket ServicesPage Waddress Page QSP-200/300 Enabler Examples QSP200EN.EXE s0,b300,i5,r Contention with Other Devices Common Problems Memory Range ExclusionCard and Socket Services Software Socket NumbersDrive\path\QSP200.SYS options OS/2 InstallationConfiguring With System Assigned Resources Command Line OptionsConfiguring With User Assigned Resources Advanced Configuration Topics Monitoring The Status Of Pcmcia Cards Invalid I/O Address When Using OS/2 Common ProblemsInsufficient Number Of Command Line Arguments Resources Not AvailableHardware Information Port AddressingScratchpad / Interrupt Status Register Auxiliary Channel RTS-CTS Handshaking Auxiliary Channel ConfigurationAuxiliary Channel Handshaking Disabled Termination Resistors 2-Wire OperationOptions External Connections QSP-200/300 adapter cable to standard female D-9 connectorsThis Page Left Blank Intentionally Specifications QSP-200/300 Version March