3 Hardware Installation

1.Turn off the power of the computer system in which the QSC(LP)-200/300 is to be installed.

2.Remove the system cover according to the instructions provided by the computer manufacturer.

3.Make any desired optional jumper setting changes.

4.Install the QSC(LP)-200/300 in any empty PCI expansion slot. The board should be secured by installing the Option Retaining Bracket (ORB) screw.

5.Replace the system cover according to the instructions provided by the computer manufacturer.

6.Attach and secure the cable connectors to the desired equipment.

7.Turn on the power of the computer system.

The output of the QSC(LP)-200/300 is a 44-pin custom connector, which is brought out to four 9-pin D-connectors via a custom cable.

J 1

Figure 3 --- Jumper/connector locations

Quatech QSC(LP)-200/300 User's Manual

8

Image 10
Contents QSCLP-200/300 Date of Purchase Model Number Page Declaration of Conformity External Connections IND Option --- Surge Suppression UpgradeGeneral Information PCI Resource MapSpecifications Troubleshooting Features QSCLP-200/300 Product Series SummarySignal Connections Hardware Configuration1 AUX1,2,3,4 pins 3 and 4, 7 and 8, 11 and 12, 15 Force High-Speed Uart Clock X8, pins 17 Hardware Installation Jumper/connector locationsWindows Configuration Windows MillenniumWindows Windows Page Windows Windows NT Viewing Resources with Device Manager AdapterPage Changing Resource Settings with Device Manager RS-422/485 Serial AdapterData Rate Multiplier Page Page OS/2 Other Operating SystemsDOS and other operating systems QTPCI.EXE QTPCI.EXE Expert Mode display Rclk DTR/DSR or RTS/CTS OperationRTS/CTS Handshake TclkAUXIN/AUXOUT Loopback Termination Resistors RS-422/485 Termination44 connector definitions RS-422/485 Peripheral ConnectionAUXOUT+ Auxout AUXIN+ Auxin GND Base Address and Interrupt Level IRQ Port Address RangeSpecifications Computer will not boot up QSCLP-200/300 Revision November 940-0146-114