Patton electronic 1070 Wiring for Multipoint Circuits, Daisy Chain Topology, Star Topology

Page 6

4.2 WIRING FOR MULTIPOINT CIRCUITS

The Model 1070 supports multi-point applications using either a star or daisy chain topology. Both topologies require special wiring, as well as specific DIP switch settings for master and slave units.

4.2.1 DAISY CHAIN TOPOLOGY

Using a daisy chain topology, you may connect several Model 1070s together in a master/slave arrangement. Maximum distance between the units will vary based upon the number of drops, data rate, wire gauge, etc. Call Patton Technical Support for specific distance estimates.

Figure 4 (below) shows how to wire the two-pair cables properly for a Model 1070 daisy chain topology. Note that the ground connection is not needed.

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT

RCV

RCV

XMT

RCV

RCV

RCV

XMT

XMT

RCV

XMT

XMT

Figure 4. Model 1070 daisy chain wiring

In a multipoint topology, you must configure the CARRIER ENABLE switch (DIP switch 8) differently for the master Model 1070 than for the slave Model 1070(s). Here are the proper DIP switch settings for a daisy chain topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

4.2.2 STAR TOPOLOGY

In a star topology, you may connect several Model 1070s together in a master/slave arrangement. Maximum distance between the units will vary based upon the number of drops, data rate, wire gauge, etc. Call Patton Technical Support for specific distance estimates.

Figure 5 (below) shows how to wire the two-pair cables properly for a Model 1070 star topology. Note that the ground connection is not needed.

HOST

 

FIRST SLAVE

SECOND SLAVE

XMT

 

RCV

RCV

 

XMT

 

RCV

 

RCV

 

RCV

 

XMT

 

XMT

 

RCV

 

XMT

 

XMT

 

 

 

 

Figure 5. Model 1070 star wiring

In a multipoint topology, you must configure the CARRIER ENABLE switch (DIP switch 8) differently for the master Model 1070 than for the slave Model 1070(s). Here are the proper DIP switch settings for a star topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

4.2 RS-232 CONNECTION

To connect the Model 1070 to data terminal hardware (PC, host, terminal, etc.), use a straight through RS-232 cable. To connect the Model 1070 to data communications hardware (modem, multiplexer, etc.), use a null modem RS-232 cable.

9

10

Image 6
Contents User Manual Service Radio and TV InterferenceCE Notice Features Description3 RTS/CTS Delay Switch Summary TableDetailed Switch Settings Carrier EnableTwisted Pair Connection Using Terminal Blocks InstallationTwisted Pair Wiring Overview Twisted Pair Connection Using RJ-11Host First Slave Other Slaves Wiring for Multipoint CircuitsDaisy Chain Topology Star TopologyLoopback Test Modes LED IndicatorsOperation Local Analog LoopAppendix a Patton Model 1070 Specifications Appendix B Patton Model 1070 Cable RecommendationsDirection Standard DCE Symptom Appendix B Troubleshooting Problemsolution Solution Straight through