Patton electronic MODEL 1075 user manual S1 Summary Table, S2 Summary Table

Page 4

3.1.1 Configuration Switch Set “S1”

The switches on Switch S1 set V.54 Test Functions. Default settings and detailed descriptions for each switch are shown below.

S1 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

S1-1 thru S1-7

Not Assigned

Off

 

 

 

 

 

S1-8

V.54 Test Functions

Off

Enabled

 

 

 

 

Switches S1-1 through S1-7: Not Assigned

Switch S1-8: V.54 Test Functions

Switch S1-8 enables or disables the Model 1075 V.54 loopback test modes.

S1-8

Activation

Description

Off

Enabled

V.54 test functions enabled

On

Disabled

V.54 test functions disabled

3.1.2Configuration Switch Set “S2”

The switches on Switch S2 set data rates, clock source, carrier control and front panel switch operation. Default settings and detailed descriptions for each switch are shown below.

S2 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

S2-1

Data Rate

On

}

56 kbps

S2-2

Data Rate

Off

S2-3

Clock Mode

On

}

Internal

S2-4

Clock Mode

On

S2-5

Carrier Control

Off

 

Forced On

S2-6

Not Assigned

Off

 

 

 

 

 

 

 

S2-7

Not Assigned

Off

 

 

 

 

 

 

 

S2-8

Front Panel Switches

On

 

Enabled

 

5

 

 

 

Switches S2-1 and S2-2: Data Rate

Switches S2-1 and S2-2 are set in combination to determine the synchronous data rate for the Model 1075.

S2-1

S2-2

Setting

Off

On

32 kbps

On

Off

56 kbps

On

On

64 kbps

Switches S2-3 and S2-4: System Clock Mode

The setting for switches S2-3 and S2-4 determines the transmitter clocking mode for the Model 1075.

S2-3

S2-4

Clock Mode

Description

On

On

Internal

System clock

 

 

 

generated internally

On

Off

External (DTE)

System clock derived

 

 

 

from terminal interface

Off

On

Receive Recover

System clock derived

 

 

 

from the received line

 

 

 

signal.

Switch S2-5: Carrier Control

 

S2-5

Carrier

Description

Off

Always On

Transmitter is always ON

On

Follows terminal

Transmitter controlled by “Control”

 

 

signal from X.21DTE (or by

 

 

“Indication” signal from X.21 DCE)

Switches S2-6 and S2-7: Not Assigned

Switch S2-8: Front Panel Switch Enable/Disable

Switch S2-8 determines whether the front panel switches may be used to perform diagnostic functions.

S2-8

Activation

Description

On

Enabled

Front panel switches may be used

 

 

to activate/terminate diagnostics.

Off

Disabled

Front panel switches will have no

 

 

effect on operation of the unit.

 

 

6

Image 4
Contents User Manual Radio and TV Interference ServiceCE Notice Configuration Switches FeaturesDescription S1 Summary Table S2 Summary TableConfiguration Straps Setting the DCE/DTE StrapOpening the Case Location of the Internal StrapsSignal InstallationConnection to the Twisted Pair Interface AC Power Connections Signal PIN#Connection to X.21 Interface LED Status Monitors Test ModesPatton Model 1075 Specifications POWER-DOWNDTE/DCE I/F Appendix B Appendix C Model 1075 Factory Replacement Parts and AccessoriesModel 1075 X.21 Interface DB15 Female Patton Model # DescriptionModel 1075 PIN Configurations