Patton electronic 1058 user manual Appendix a, LAN Connection, Transmission Line, Vdsl Line Rate

Page 22

APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

VDSL Connection: RJ-45 and Terminal Block

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 VDSL LINE RATE

Model 1068—16.67 Mbps, symmetric upstream/downstream. Additional symmetric and asymmetric rates are available via DIP switch settings.

Model 1058—Fixed 12.5 Mbps, symmetric upstream/downstream.

A.4 VDSL DISTANCE

6,000 ft (1.83 km) at 1.56 Mbps upstream/4.17 Mbps downstream

Note Distances depend on selected line rate.

A.5 VDSL SURGE SUPPRESSOR

Gas tube with maximum current surge: 20 kA (8120 s).

A.6 LED STATUS INDICATORS

Power (Green)

VDSL: Link (Green) & QOL (Red)

Ethernet: Link (Green), Collision (Yellow), Duplex (Yellow), 10/100M (Yellow), Transmit (Yellow), and Receive (Yellow)

A.7 POWER SUPPLY

Input power: 5 VDC, 1A

Power consumption: 450 mA at 5 VDC

External AC and DC options:

AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

DC: 12 VDC, 24 VDC and 48 VDC

22

Image 22
Contents User Manual Contents Distance Chart, Based on 24 AWG 0.5 MM Vlink Series Interface Pin AssignmentRadio and TV Interference Warranty InformationCE Notice FCC Part 68 DV Version only Industry Canada Notice Service Tel +1 301 Email support@patton.comGeneral Information FeaturesDescription Shows a typical point-to-point application Installation Standalone Unit InstallationRack Card Installation Vlink modem rack cardsConnecting the TWISTED-PAIR Line Interface Vlink modem RJ-45 twisted pair line interfaceConnecting the 10/100BASE-T Ethernet Interface Vlink modem 10/100Base-T RJ-45 Connector PinoutConnecting the POTS/ISDN Line Connecting the 10/100Base-T Ethernet Port to a HubConnecting the 10/100Base-T Ethernet Port to a PC DTE 10/100Base-T DTEConnecting Power Vlink RJ-45 POTS/ISDN interfaceConfiguration Model 1068 only Configuring the Hardware DIP SwitchesSwitch toggle S1-1 Setting Configuring DIP Switch S1Switch S1-1 Ethernet Auto Sense Switches S1-2 and S1-4 Data RateS1-2 S1-3 S1-4 Asymmetric Line Rates DS/US S1-5 S1-6 S1-7 S1-8 Reserved for future useOperation Power UPFront Panel LED Status Monitors Description LEDLED is solid yellow and the Vlink Link LED is Off QOL Appendix a LED Status IndicatorsPower Supply LAN ConnectionDimensions Temperature RangeHumidity Appendix B Patton Model # DescriptionAppendix C 1068DVRC/CPVdsl Interface Appendix D10/100BASE-T Interface POTS/ISDN InterfaceSymm Line Rate DS/US Distance in feet km Appendix EAsymm Line Rate DS/US Distance in feet km Copyright Patton Electronics Company All Rights Reserved
Related manuals