Patton electronic 2190 Loop Test Functions, Display Current Configuration and Stored Profiles, Bn

Page 7

 

 

AT Command Sets (continued)

 

 

Command

Description

 

 

 

&Tn

 

Loop Test Functions

 

AT&T0

Terminates test in progress.

 

AT&T1

Initiates local analog loopback.

 

AT&T3

Initiates local digital loopback.

 

AT&T4

Enables digital loopback acknowledgment for remote

 

 

request.

 

AT&T5

Disables digital loopback acknowledgment for remote

 

 

request. (Default)

 

AT&T6

Requests a remote digital loopback (RDL).

 

AT&T7

Requests a remote digital loopback (RDL) with self

 

 

test.

 

AT&T8

Initiates local analog loopback with self test.

 

 

 

&V

 

Display Current Configuration and Stored Profiles

 

 

Reports the current (active) configuration, the stored

 

 

(user) profiles, and the four stored telephone numbers.

 

 

 

&V1

 

Display Modem Connect Status

&Wn

 

Store Current Configuration

 

AT&W0

Stores the current configuration as profile 0.

 

AT&W1

Stores the current configuration as profile 1.

 

 

 

&Yn

 

Profile Selection

 

AT&Y0

The modem will use profile 0. (Default)

 

AT&Y1

The modem will use profile 1.

 

 

 

&Zn=m

 

Store Telephone Number

 

 

Stores telephone number for later use n= to 3,

 

 

m = dialstring.

 

 

 

%C

 

Enable/ Disable Data Compression

 

AT%C0

Disables data compression.

 

AT%C1

Enables MNP 5 data compression negotiation.

 

AT%C2

Enables V.42bis data compression.

 

AT%C3

Enables both V.42bis and MNP 5 data compression.

 

 

(Default)

 

 

 

%En

 

Enable/Disable Line Quality Monitor and Auto-

 

 

Retrain or Fallback/Fall Forward

 

AT%E0

Disables line quality monitor and auto-retrain.

 

AT%E1

Enables line quality monitor and auto-retrain.

 

AT%E2

Enables line quality monitor and fallback/fall forward.

 

 

(Default)

 

 

 

 

 

 

AT Command Sets (continued)

 

 

Command

Description

\An

 

 

Select Maximum MNP Block Size

 

AT\A0

64 characters.

 

AT\A1

128 characters. (Default)

 

AT\A2

192 characters.

 

AT\A3

256 characters.

 

 

 

 

\Bn

 

AT\B1-

Transmit Break to Remote

 

 

Break length in 100 ms units. (Default=3.) (Non-error

 

 

\B9

corrected mode only.)

 

 

 

 

 

 

 

 

\Kn

 

Break Control

(A)Break received from DTE while in connect state during on line mode:

\K0

Enter on-line command mode, no break sent to the

 

remote modem.

\K1

Clear data buffers and send break to remote modem.

\K2

Same as 0.

\K3

Immediately send break to remote modemy.

\K4

Same as 0.

\K5

Send break to remote modem in sequence with

 

transmitted data. (Default)

(B)\Bn command; received from DTE while in on line

 

command state:

\K0

Purge buffers, immediately send break to remote

 

modem.

\K1

Purge buffers, immediately send break to remote

 

modem.

\K2

Immediately send break to remote modem..

\K3

Immediately send break to remote modem.

\K4

Send break to remote modem with data.

\K5

Send break to remote modem with data.

(C)Break received from remote modem while in connect state during non error corrected connection:

\K0

Purge buffers, immediately send break to DTE.

\K1

Purge buffers, immediately send break to DTE.

\K2

Immediately send break to DTE.

\K3

Immediately send break to DTE.

\K4

Send break to DTE in sequence with data.

\K5

Send break to DTE in sequence with data.

11

12

Image 7
Contents User Manual Radio and TV Interference Table of ContentsWarranty Information SectionFCC Information ServiceFeatures Package ContentsConnecting Power Connecting to the Serial PortConnecting to the Phone Lines Connecting to the Microphone MICAT Command Sets AT CommandsSelect Sync/Async Mode DTR. DefaultRestore Factory Configuration Profile Second. DefaultEnable/Disable Line Quality Monitor and Auto Display Current Configuration and Stored ProfilesStore Current Configuration Enable/ Disable Data CompressionDial Codes Dial Codes+MS SUB Parameter Definitions FAX CommandsFAX Class 1 Commands FAX Class 2 Commands+FDIS= Voice CommandsCommands to Change or Read Registers +FDISRegister Description AT?Operations Appendix a Patton Electronics Model SpecificationsLED Status Monitors +FCERROR RTS