3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Interconnecting cables shall be acceptable for

external use and shall be rated for the proper applica-

tion with respect to voltage, current, anticipated tem-

CAUTION perature, flammability, and mechanical serviceability.

The Model 2173R supports communication between two peer Ethernet LAN sites over a distance of up to 5,500 ft (1.6 km) over 24 AWG (0.5 mm) twisted-pair wire.

Note Actual distance and link performance may vary depending on the environment and type/gauge of wire used.

Follow the steps below to connect the Model 2173R CopperLINK Inter- faces.

Note The Model 2173R units work in pairs. One of the units must be configured as a (L) Local unit, and the other unit must be config- ured as a (R) Remote unit. It does not matter which end is the L and which is the R. The link is always initiated by the R unit. As long as the L unit is powered on, the R unit can establish a link by being powered on or by having its power reset.

1.To function properly, the two Model 2173Rs must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

10

Image 10 Contents
User Manual Contents Sample Rates/Distance Chart, Based on 24 AWG 0.5 MM Compliance Warranty InformationLow-Voltage Direcive Safety EMC ComplianceAuthorized European Representative ServiceCE Declaration of Conformity Tel +1 301 Email support@patton.comFor AC powered devices which have 3 conductor Safety When Working with ElectricityHave an earth ground Page General Information FeaturesDescription Installation Typical applicationConnecting the TWISTED-PAIR Line Interface 2173R RJ-45Connecting the 10/100BASE-T Ethernet Interface Model 2173R RJ-45 twisted pair line interfaceConfiguration Connecting PowerConfiguring the Hardware DIP Switches Switch toggle Power UP Configuring DIP Switch S1Operation Front Panel LED Status Monitors Temperature Range LED Status IndicatorsPower Supply DimensionsAppendix B Patton Model # DescriptionRJ-45 Appendix C10/100BASE-T Interface Copperlink InterfaceThroughput Distance At Max Rate Mode Feet kmAppendix D SecondCopyright Patton Electronics Company All Rights Reserved