Patton electronic 1008 Host First Slave Other Slaves, Connection to the EIA/TIA-574 Interface

Page 9

Figure 6 (below) shows how to wire the two-pair cables properly for a Model 1008 daisy chain topology. Note that the ground connection is not needed.

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT+

---------------------RCV+-----------------------

RCV+

XMT-

---------------------RCV- -----------------------

RCV-

RCV+

---------------------XMT+-----------------------

XMT+

RCV-

---------------------XMT- -----------------------

XMT-

Figure 6. Daisy chain wiring for Model 1008 host and slaves

4.3 CONNECTION TO THE EIA/TIA-574 INTERFACE

The Model 1008 is designed to plug directly into the DB-9 serial port of an EIA/TIA-574 DTE device (PC, laptop, host). If you must use a cable to connect the Model 1008 to the DTE device, make sure that it is a straight through cable of the shortest possible length—we recommend 6 ft or less. The DB-9 connector on the Model 1008 is wired according to the EIA/TIA-574 Standard, as shown below:

EIA/TIA-574 Standard

DB-9 SIGNAL

1-----------------CD

2-----------------RD

3-----------------TD

4-----------------DTR

5-----------------SG/FG

6-----------------DSR

7-----------------RTS

8-----------------CTS

9-----------------(Optional 6-12 VDC power)

Note: The Model 1008 is configured as a DCE (Data Communications Equipment), and is therefore designed to connect to a DTE (Data Termination Equipment). If you need to connect the Model 1008 to another DCE device, please call Patton Technical Support at (301) 975-1007 for details on constructing the proper crossover cable.

4.4 OPERATING THE MODEL 1008

Once the Model 1008 is properly installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no “ON/OFF” switch. All data signals from the RS-232 and RS-485 interfaces are passed straight through. Additionally, one hardware flow control signal is passed in each direction.

15

APPENDIX A

MODEL 1008 SPECIFICATIONS

Transmission Format:

Asynchronous

 

 

 

 

Data Rate:

Up to 115,200 bps

 

 

 

 

Range:

Up to 9 miles

 

 

 

 

Serial Interface:

DB-9, male or female; wired as a DCE

 

 

according to EIA/TIA-574 Standard.

Transmit Line:

2, 4 wire unconditioned twisted pair

Transmit Mode:

4-wire, full or half duplex; 2-wire half duplex

Control Signals:

DSR turns “ON” immediately after the

 

 

terminal raises DTR; DCD turns “ON” after

 

 

recognizing the receive signal from the line;

 

 

CTS turns “ON” after the terminal raises

 

 

RTS.

 

 

 

 

 

 

RTS/CTS Delay:

8 mSec or “no delay”

 

 

Carrier:

The carrier is switch selected either

 

 

continuous operation or switched operation,

 

 

controlled by RTS

 

 

 

 

Surge Protection:

600W power dissipation at 1 mS

Power:

Draws operating power from EIA/TIA-574

 

 

data and control signals; no AC power or

 

 

batteries required. If necessary, 6-12 VDC

 

 

can be applied to pin 9 of the EIA/TIA-574

 

 

interface.

 

 

 

 

 

 

Temperature:

0 to 50º C

 

 

 

 

 

 

Humidity:

5 to 95%, non-condensing

 

 

Size:

”2.50" x 1.2" x .75"

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 1008 Distance Table (miles)

 

 

 

 

 

 

 

 

 

 

 

 

Data Rate

 

 

Wire Gauge

 

 

 

(kbps)

19

 

22

 

24

 

26

 

 

115.2

3.5

 

2.6

 

1.4

 

0.9

 

 

38.4

5.0

 

2.9

 

2.2

 

1.5

 

 

9.6

7.1

 

4.6

 

3.5

 

2.8

 

 

1.2

9.0

 

6.5

 

5.0

 

3.9

 

16

Image 9
Contents User Manual Service Radio and TV InterferenceCE Notice Features Accessing the DIP SwitchesDescription Switch S1 Summary Table factory defaults in bold DIP Switch S1 SettingsS1-2 and S1-3 2-wire/4-wire Modes S1-4 Echo ModeTypical Applications DIP Switch S2 SettingsTwisted Pair Connection Twisted Pair Connection Using Terminal BlocksSignal Twisted Pair Connection Using RJ-11 or RJ-45RJ-11 RJ-45Wiring for Multipoint Circuits Signal PIN#Star Topology Host First Slave Second SlaveAppendix a Model 1008 Specifications DB-9 SignalHost First Slave Other Slaves Connection to the EIA/TIA-574 InterfaceCopyright Patton Electronics Company All Rights Reserved