Patton electronic user manual Model 571/581 Specifications

Page 5

APPENDIX A

MODEL 571/581 SPECIFICATIONS

Environment:

Category-5 Interfaces that utilize the RJ-45

 

connector, including RS-422, 423, 10Base-

 

T, Token Ring, Fast Ethernet, 100Base-T

 

and ATM on a 4-wire interface.

Connectors:

RJ-45 Female

Response Time:

Clamped to 13 V after 0.1 µs

Characteristic

 

Impedance:

100 Ohms

NEXT Loss:

Model 571 - worst pair Better than -45 dB at

 

100 MHz; Model 581 - worst pair Better

 

than -43 dB at100 MHz

Surge Clamp

 

Voltage:

Model 571 - 13 V max with 1 KV Input;

 

Model 581 - 15 V max with 2 KV Input

Surge Rating:

IEC 801.5 Standard Level

DC Clamp Voltage:

Common Mode to Gnd, each line7.5 V @ 50

 

mA; Differential mode, per pair 8.1 V @ 50

 

mA

Insertion Loss:

Less than 0.4 dB at 100 MHz (including

 

connector)

Return Loss:

Better than 14 dB

Group Delay:

None, 1 MHz to 100 MHz

Series Resistance:

Less than 400 milliohms

Grounding:

External ground strap provides separate

 

unit-ground to chassis-ground contact

Dimensions:

2.0L x 1.0”D

APPENDIX B

MODEL 571/581 INTERNATIONAL ELECTROTECHNICAL

COMMISSION (IEC) COMPLIANCE

Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)

Effective January 1996 the European Economic Community will require that all electronic devices be tested and comply with all applicable International standards relating to the product type and category of use. Electromagnetic Compatibility Directive 89/336/EEC specifically addresses communication line surge protection devices, since conformity to immunity standard EN50082-1:1992 is mandatory. The EN50082-1:10992 standard incorporates International Organization for Standardization (ISO) publications 801.2 and 801.4, which describe Electrostatic Discharge and Electrical Fast Transient requirements. ISO 801.5 describes Surge Immunity Requirements and is expected to be adopted as a mandatory requirement under EN50082-1 by the Technical Committee. in 1996. Any protector sold into the international community must meet these standards. This device has been tested* and found to comply with these standards as evidenced by its CE mark.

*Note: All test results are for the Model 571/581 alone, not including the standard 6 inch (15.25) patch cable that is shipped with the unit.

IEC 801-5 Threat Levels as a Function of Class

Class

Sym. Lines Coupling Mode

 

 

Line-GND, Zs=42 Ohms

 

 

 

1

 

1.0 kV

 

 

24 A

2

 

1.0 kV

 

 

24 A

3

 

2.0 kV

 

 

48 A

4

 

(n/a)

 

 

(n/a)

5

 

4.0 Kv

 

 

95 A

Wave

(1.2 x 50 µs)

Forms

(1.2 x 50 µs)

 

 

 

Table 1. IEC Threat Levels as a Function of Class.