Patton electronic 552 user manual Service, CE Notice, Features, Description

Page 2

1.0 WARRANTY INFORMATION

Patton Electronics warrants all Model 552 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.1 SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at: (301) 975-1007; http://www.patton.com; or, support@patton.com.

NOTE: Packages received without an RMA number will not be accepted.

Patton Electronics' technical staff is also available to answer any questions about the installation or use of your Model 552. Technical Service hours are: 8AM to 5PM EST, Monday through Friday.

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If you have any questions while installing or using this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.

2.1FEATURES

Uses a multi-stage hybrid circuit for the best possible protection

Handles surge energy up to 1.5 kW

Conforms to the UL497A telco specification (except E1 versions)

Available for ISDN-U (8-wire), ISDN-ST (4-wire), T1, E1, ISDN PRI, DDS, leased line and dial up configurations

Diverts surges directly to chassis ground through braided metal ground strap

Equipped with two RJ-45 jacks or four BNC connectors

Easy to install

Made in the U.S.A.

2.2DESCRIPTION

The potential threats to ISDN and Telco hardware are vast: lightning, AC power induction, electrostatic discharge, ground potential differences, EMI/RFI interference and more. The Patton Model 552 has been designed to greatly reduce these risks. Just attach one unit to each of your telco ports and rest easy.

The Model 552 connects directly between twisted pair telco cables and their respective I/O ports. Grounding is accomplished using an external ground strap that provides a separate unit-ground to chassis- ground connection. By shunting threatening voltages directly to chassis ground, the Model 552 insures data integrity and protects connected equipment from damage.

The Model 552 uses a solid state design and sophisticated multistage hybrid circuits to achieve maximum protection without performance loss. Eight versions are available: Model 552-ST, 552- D8, and 552-L8 protect all 8 pins; Model 552-D6 protects six pins; Models 552-DDS, 552-D4, 552-U, 552-L4, 552-E1, 552-E1 CX, and 552-T1 protect four pins; and, Model 552-D2 protects two pins. All versions provide up to 1500 Watts of data line protection.

NOTE: Model 552-L8 may be used to protect Leased Line, DDS, T1, E1, ISDN PRI, and ISDN BRI “U” and “ST” interfaces.

WARNING!: This product will not provide complete protection should your equipment or building be subject to a direct lightning hit.

Image 2
Contents User Manual CE Notice ServiceFeatures DescriptionModel 552 Specifications How to Connect the ModelModel 552-D6